Bosch Appliances Home Security System D7412G User Manual

Page of 142
D9412G/D7412G | Program Entry Guide | 6.0 RADXAUX1
EN | 121
Bosch Security Systems | 1/04 | 47775E
In order to use an off-the-shelf external modem and a D9133DC serial module to connect to the control
panel using RAM, use the following settings:
1.
 
RADXAUX1\ENHANCED COMM\Enhanced Comm\No
2.
 
RADXAUX1\SDI RAM PARAMETERS\Enable SDI RAM\Yes
3.
 
RADXAUX1\SDI RAM PARAMETERS\Callback Enabled\No
4.
 
RADXAUX1\SDI RAM PARAMETERS\RAM IP Address 1-4\0
5.
 
RADXAUX1\SDI RAM PARAMETERS\Enable Ext Modem\Yes
6.
 
RADXAUX1\SDI RAM PARAMETERS\Answer Armed\1 to 15
7.
 
RADXAUX1\SDI RAM PARAMETERS\Answer Disarmed\1 to 15
8.
 
RADXAUX1\SDI RAM PARAMETERS\RAM Line Monitor\No
9.
 
RADXAUX1\SDI RAM PARAMETERS\Seize Relay\No
10.
 
RADXAUX1\SDI RAM PARAMETERS\Modem Init String\ATE0
11.
 
RADXAUX1\SDI RAM PARAMETERS\RAM Dial String\ (blank)
12.
 
RADXAUX1\SDIRAM/ENHANCED CONF\Baud Rate\9600
13.
 
RADXAUX1\SDIRAM/ENHANCED CONF\Parity/Stop No\1
14.
 
RADXAUX1\SDIRAM/ENHANCED CONF\RTS Control\ON
15.
 
RADXAUX1\SDIRAM/ENHANCED CONF\DTR Control\ON
16.
 
RADXAUX1\SDIRAM/ENHANCED CONF\9133 Supervision\No
17.
 
9000MAIN\PANEL WIDE PARAMETER\Enhanced Routing\RG1 Primary SDI\No
18.
 
9000MAIN\PANEL WIDE PARAMETER\Enhanced Routing\RG1 Backup SDI\No
19.
 
9000MAIN\PANEL WIDE PARAMETER\Enhanced Routing\RG2 Primary SDI\No
20.
 
9000MAIN\PANEL WIDE PARAMETER\Enhanced Routing\RG2 Backup SDI\No
21.
 
9000MAIN\PANEL WIDE PARAMETER\Enhanced Routing\RG3 Primary SDI\No
22.
 
9000MAIN\PANEL WIDE PARAMETER\Enhanced Routing\RG3 Backup SDI\No
23.
 
9000MAIN\PANEL WIDE PARAMETER\Enhanced Routing\RG4 Primary SDI\No
24.
 
9000MAIN\PANEL WIDE PARAMETER\Enhanced Routing\RG4 Backup SDI\No
25.
 
The control panel reset pin can be up or down.
26.
 
The modem at the control panel location must be set for 9600 baud and echo off. This information
must be written to the modem configuration area. Hyperterminal can be used to send the following
Hayes modem commands (see the Modem Manual for command syntax):
 
ATS37=9 (set baud rate to 9600)
 
ATE0 (eliminate echo)
 
AT&W0 (write configuration to modem memory, not echoed)
27.
 
Ensure the modem at RPS is set up for 9600 baud.
28.
 
From the control panel communication window on RPS, connect by modem at 9600 baud.