Bosch Appliances Home Security System D7412G User Manual

Page of 142
D9412G/D7412G | Program Entry Guide | 2.0 9000MAIN
EN | 13
Bosch Security Systems | 1/04 | 47775E
Table 6:
Modem IIIa
2
 Communication Format
Data - User ID Numbers
Point/User Flag
NO
Point/User Flag
YES
000
000
001 to 005
001 to 005
006 to 013
601 to 608
014 to 021
701 to 708
022 to 029
801 to 808
030 to 037
B01 to B08
038 to 045
C01 to C08
046 to 053
D01 to D08
054 to 061
E01 to E08
062 to 069
F01 to F08
070 to 249
000
Table 7:
Modem IIIa
2
 Communication Format
Data – Point Numbers
Point/User Flag
NO
Point/User Flag
YES
001 to 008
100 to 800
009 to 024
101 to 116
025 to 040
201 to 216
041 to 056
301 to 316
057 to 072
401 to 416
073 to 088
501 to 516
089 to 104
601 to 616
105 to 120
701 to 716
121 to 136
801 to 816
153 to 168
217 to 232
169 to 184
317 to 332
185 to 200
417 to 432
201 to 216
517 to 532
217 to 232
617 to 632
233 – 247
717 to 731
Independent Zone Control Notice: When using
Independent Zone Controls (IZC) to send
Opening/Closing Reports by point, do not duplicate
reporting independent point numbers with User ID
Reports (see Section 3.1 Passcode/Token Worksheet). For
example: If an IZC is connected to Point 8, User ID
8 should not be used.
D6000: Opening/Closing User ID numbers are
identified at the receiver as ZONEs (same
identification as independent points).
Table 8:
Zones
User ID Number
Zone
1
B
2
C
3
D
4
E
5
F
6
6
7
7
8
8
91
1
92
2
93
3
94
4
95
5
96
0
D6500/D6600 Receiving BFSK Format:
Opening/closing User ID numbers are identified at
the receiver as ZN (same identification as
independent points). The ZN numbers are based on
the tens digit of the User ID number. This only
applies for Users 000 through 099. Users 100
through 249 do not report in BFSK format.
DTMF Dialing
Default:
Yes
Selection:
Yes or No
Yes
Dials the programmed phone
number(s) using DTMF.
No
Pulse dialing only.
Use dual-tone multi-frequency (DTMF) to dial the
central station receiver phone number(s) for event
reports, and/or the RPS.