D9412G/D7412G | Program Entry Guide | 2.0 9000MAIN
EN | 36
Bosch Security Systems | 1/04 | 47775E
Figure 2: Account Number Entry
2
2
3
3
4
4
5
5
1
1
2
3
4
5
6
7
1
1 -
RPS account number entry
2 -
Corresponding D5200 account number digits
3 -
Digits 1 and 2
4 -
Digits 3 and 4
5 -
Digits 5 and 6
6 -
Digits 7 and 8
7 -
Digits 9 and 10
Although the D5200 allows the character
“A” to be entered into the account, do
NOT use this character for the account
number.
Make sure your central station receivers
(D6500 MPU version 1.06 or D6600 CPU
version 01.01.04) and your automation
software are compatible with ten-digit
account numbers before programming a
ten-digit account number in a 9000 Series
control panel.
A# FA Bypass Max
Default:
1
Selection:
1 to 99
Specify the maximum number of combined
Controlled points that can be faulted or bypassed
when arming this area.
See the prompts 
P## FA Retrnable
 and 
P## BA
Retrnable
 in Section 4.1.1 Point Responses for
returning a point to the system when the point
returns to normal or when the area is disarmed.
Users can bypass more points than the
number entered here during the disarmed
state. It is only when the user attempts to
Bypass Arm an area (or areas) that this
restriction is enforced.
0101
0101
0101
Points need Bypassable programmed Yes
to be bypassed or force armed. Force
arming does not bypass 24-hour points.
A# Delay Res
Default:
No
Selection:
Yes or No
Yes
Point Restoral Report is not sent until
the bell time expires or user
acknowledges alarm condition.
No
Restoral Reports are sent when point
restores, regardless of bell time.
A# Exit Tone
Default:
Yes
Selection:
Yes or No
Sound an exit tone during exit delay at all command
centers assigned to this area.
De-selecting individual command
centers for exit tones: Exit tones for
programming the CC Exit Tone as No can
be turned off for individual command
centers (based on their CC# 1 through 8).
A# Exit Dly Time
Default:
60
Selection:
Blank (0) to 600 ( in 5 second
increments)
Exit delay time for this area when Master Exit or
Perimeter Exit arming.
Points programmed for instant alarms
generate alarms immediately, even during
exit delay. To prevent instant alarms on
points, the user must cause a fault to leave
the building, program P### Type in the
Point Index as 3 (Interior Follower).