Bosch Appliances Home Security System D7412G User Manual

Page of 142
D9412G/D7412G | Program Entry Guide | 2.0 9000MAIN
EN | 64
Bosch Security Systems | 1/04 | 47775E
L## User Cmd 9
Default:
See 
Program Record Sheet
Selection:
Blank or E
#24 User COMMAND 9 [COMMAND][9]
Can be used in Function Menu. Generate the alarm
programmed at COMMAND 9 in the RADXPNTS
Handler.
L## Bypass a Pt
Default:
See 
Program Record Sheet
Selection:
Blank or E
#25 Bypass a Point [COMMAND][0]
Bypass points with this authority level
L## Unbypass a Pt
Default:
See 
Program Record Sheet
Selection:
Blank or E
#26 Unbypass a Point [COMMAND][0][0]
Unbypass points with this authority level.
L## Reset Sensors
Default:
See 
Program Record Sheet
Selection:
Blank or E
#27 Reset Sensors [COMMAND][4][7]
Reset sensors with this authority level.
L## Change Relay
Default:
See 
Program Record Sheet
Selection:
Blank or E
#28 Change Relays [COMMAND][5][4]
Set RELAY ON? and reset RELAY OFF? relays in
the control panel.
Do not use the Chg Relays? function to
toggle relays reserved for special
functions. Special function relays are Area
and Panel Wide Relay functions as well as
relays assigned to CC# Entr Key Rly?.
L## Remote Program
Default:
See 
Program Record Sheet
Selection:
Blank or E
#29 Remote Programming [COMMAND][4][3]
Initiate a RAM session once the phone rings at the
control panel.
L## Move to Area
Default:
See 
Program Record Sheet
Selection:
Blank or E
#30 Move to Area [COMMAND][5][0]
Temporarily switch to a different area and perform
command center functions related to the area to
which the command center is switched.
L## Display Rev
Default:
See 
Program Record Sheet
Selection:
Blank or E
#32 Display Software Revision
[COMMAND][5][9]
Display the control panel software revision 
9412
REV ##.##
.
L## Service Walk
Default:
See 
Program Record Sheet
Selection:
Blank or E
#33 Service Walk Test (MENU FUNCTION only)
Initiate a Service Walk Test for all 24-hour
Interior/Perimeter Controlled points in the control
panel.
Points are not included in this test if:
 
Points are in an area that is already in a Walk
Test Mode.
 
Points are assigned to an area that is not enabled
A# Area On
.
 
Points are in an area that is Master or Perimeter
armed.
 
When a Service Walk Test is initiated, one
person can test all the points in the control panel
without assistance. The following features are
provided with the Service Test Mode:
Display tells you exactly how many points
can be tested.
A Battery and Bell Test does not occur
during this Walk Test.
The test ends once all points are tested or
until the test times out after 20 minutes of
inactivity.
Local event printing without alarm
annunciation or reporting to the central
station receiver.