Bosch Appliances Home Security System D7412G User Manual

Page of 142
D9412G/D7412G | Program Entry Guide | 1.0 Introduction
EN | 9
Bosch Security Systems | 1/04 | 47775E
1.7
Programming the Control Panel
with the D5200 Programmer
Latch the jumper in the upper right hand corner of
the control panel labeled as RESET on the PCB and
Reset Pin on the faceplate.
Connect the molex end of the cord to the connector
labeled PROG on the PCB and PROG CONN on
the faceplate.
Always initiate a control panel copy at the
NEWRECORD
 or 
FILENAME
 display when pressing
the [RECV] (copy) key of the D5200.
Always initiate a control panel load at the
FILENAME
 prompt or set as factory default at  the
NEWRECORD
 prompt when pressing the [SEND]
(load) key.
Disconnect the D5200 before releasing the reset pin.
Do not leave the D5200 connected to the
PROG connector without latching the
RESET pin. Doing so causes 
SDI ##
TROUBLE
 and 
CALL FOR SERVICE
 to
display on the command centers. Door
controllers also activate depending upon
the SDI failure DIP switch setting.
Table 5:
Programming Error Displays
Display
Description
INCOMPATIBLE PANEL
You are connected to the
wrong control panel or
using the wrong handler.
Check the faceplate for the
model number and the
handler title.
CHECK CORD/RESET
PIN
Check the cord and reset
pin
0101
0101
0101
There is a 5 second to 25 second pause
after the reset pin is unlatched during
which the control panel scans all the
points and properly displays, logs, and
reports them.