Four door states: Locked, Unlocked, Secured, Fire Unlock.
Disarm states using a token
Pre-warn for holding door open too long
Disarm system before or after a door opens
Automatic Unlock door on disarm, Locked Door when armed
Optional Deactivate strike when the door opened
Interlock point assignment to prevent access until interlock point is normal.
1000 Cards/Tokens
Fourteen programmable levels of access authority
Users can be added or deleted remotely, locally and with Command Center
2.3.2
Displays and Reports
Access Granted with user ID and User Name
No Entry with user ID and door User Name
Request to Enter with door point text
Request to Exit with door point text
Door Unlocked with door point text
Door Locked with door point text
Alarm Point ### with door point text
Trouble Point ### with door point text
Missing Point ### with door point text
Please Close Door with door point text
2.4
Materials Included
Bosch Security Systems ships the D9210B Access Control Interface module pre-assembled from the factory with a power
supply, in its own can, or as a unit less can. You will receive the following parts with your package depending upon what
model is ordered, (see Section 2.5 Ordered Separately, p.11).
D136 removable relay mounted on the board.
Battery Leads (for the D9210BLC).
1 k
Ω
 1/2 watt end of line resistor.
Literature Pack containing: D9210B Operation and Installation Guide (P/N:32206), D9210 Program Entry
Guide 
(P/N:32207), ACCESS Program Record Sheet (P/N:32208), and Power Supply Installation
Instructions.
Hardware pack containing: three #6x3/8 self-tapping sheet metal screws to secure the module on the
mounting skirt or the enclosure. Two strain relief cable ties.