NOTE:
A 24 VDC power supply may be used for the door
strike if necessary. (See Figure 5)
Strike and
D9210B
This color code does not match
all readers. Make a note of the
color code of the reader you are
using.
1
PWR +
7
SDIB
6
SDIA
5
COM
8
T +
10
ZN +
9
ZNCOM
2
LCKN/C
3
LCKCOM
4
LCKN/O
13
REX
12
COM
11
RTE
16
DATA 1
17
BUZZER
18
LED
15
DATA 0
14
+5.20V
D0
READER
OPER
MON
D1
READER
1
2
3
4
5
6
ON
D9210B
(red)
12 VDC AUX
Power Supply
UL Listed for Fire
DC OUTPUT
+
-
(black)
(white/yellow)
(green)
SDI
PWR
SDI
A
SDI
B
SDI
COM
Security
Panel
(black)
EMERGENCY
EGRESS
DOOR
DOOR CONTACT
(NORMAL E.O.L.
IN CIRCUIT)
1K
E.O.L.
RTE/REX
(NORMAL
OPEN)
(white)
(green)
(red)
(brown)
12 VDC
BUZZER
12 VDC READER
(+)
(-)
(yellow)
TAMPER SWITCH
(NORMAL OPEN)
(black)
12 VDC
DOOR
STRIKE
Some jurisdictions will not allow the
use of Emergency Egress as your sole
means of escape. If this feature is used,
it still may be necessary to provide listed
panic hardware. Consult your local
authority having jurisdiction (AHJ) prior to
nstallation.
DO NOT power the
D9210B Module
with 24 VDC.
CAUTION
CAUTION
EMERGENCY EGRESS Switch should be
Normally Open (NO) for Coil Locks and
Normally Closed (NC) for Maglocks