ICP-CC488 | Installation Guide | 3.0  
System Operations 
EN | 14 
 
 
Bosch Security Systems, Inc. | 12/08 | F01U089457-02 
 
3.0   System Operations 
This section explains the general operations of the 
system: arming and disarming the system in the three 
modes, isolating zones, initiating codepad alarms, 
and determining a fault. 
3.1 
Arming the System in AWAY Mode 
Arming the system in AWAY Mode is normally 
performed when you leave the premises and require 
that all zones are activated in a ready state to detect 
an intrusion.   
There are two different methods to arm the system in 
AWAY Mode. You can always use method one.  
You can use method two only if Option 2 is enabled 
in Location 497 (refer to Section 18.6 Consumer 
Options 2 
on page 83). 
If you must isolate a zone (or zones) before arming 
the system in AWAY Mode, refer to Section 3.11 
Isolating Zones 
on page 17. 
 
Single button arming in AWAY Mode 
reports as User Code number 16. 
To arm the system in AWAY Mode (method one): 
Enter your code and press [AWAY]. 
Two beeps sound, the AWAY indicator lights, and 
Exit Time starts. 
To arm the system in AWAY Mode (method two): 
 
Select Option 2 in Location 497 to 
enable single button arming in AWAY 
Mode (refer to Section 18.6 Consumer 
Options 2 
on page 83). 
1.  Press and hold [AWAY]. 
2.  When two beeps sound, release the button. 
The AWAY indicator lights and Exit Time starts. 
If a zone is not sealed at the end of Exit Time, the 
zone is automatically isolated and its indicator is lit 
on the remote codepad. The zone becomes an active 
part of the system again as soon as it is resealed. For 
example, if a window is open when Exit Time 
expires, the window is not an active part of the 
system until it is closed. Opening the window after 
Exit Time expires causes an alarm. 
Forced Arming 
Arming the system when a zone is not sealed is 
known as forced arming. Refer to Section 14.3.7 Zone 
Options 2
 on page 63 to enable forced arming for 
each zone. 
If the AWAY indicator does not light and a long 
beep sounds when you attempt to arm the system in 
AWAY Mode, forced arming is not permitted. If this 
is the case, you seal all zones or manually isolate 
them before you can arm the system. 
3.2 
Disarming the System from AWAY 
Mode 
When you enter the premises after the system is 
armed in AWAY Mode, you must disarm the system 
from AWAY Mode to disable detection devices that 
activate the sirens, strobe, and bell outputs. 
If there was an alarm prior to disarming the system 
from AWAY Mode, a zone indicator flashes, 
indicating a previous alarm in that zone. 
To disarm the system from AWAY Mode: 
1.  Enter your code and press [AWAY]. 
2.  Two beeps sound and the AWAY indicator is 
extinguished.   
3.3 
Arming the System in STAY Mode 1 
STAY Mode 1 is used when you need to arm the 
perimeter and unused areas of the premises to detect 
a would-be intruder entering the premises, while at 
the same time being able to move freely within an 
area that is automatically isolated.   
Only the installer can program zones to be 
automatically isolated in STAY Mode 1. Refer to 
Section 14.3.7 Zone Options 2 on page 63 for more 
information on setting zones to be automatically 
isolated in STAY Mode 1. 
There are two methods to arm your system in STAY 
Mode 1. You can always use method one. You can 
use method two only if Option 2 is enabled in 
Location 497 (refer to Section 18.6 Consumer Options 2 
on page 83). 
If the system reports to a base station, it sends a 
Partial Close Report (Contact ID Event Code 456). 
Entry Guard Timer for STAY Mode 
When arming the system in STAY Mode 1, an 
optional entry timer called Entry Guard Timer for 
STAY Mode can be used to delay the sirens, strobe, 
and bell outputs if a zone that is not automatically 
isolated activates an alarm. Entry Guard Timer for 
STAY Mode is the delay time used for all zones, 
except 24-Hour zones, when the system is armed in 
STAY Mode 1 or STAY Mode 2.  
If the Entry Guard Timer for STAY Mode is 
programmed and a zone that was not automatically 
isolated is activated, the codepad beeps twice per sec 
until the Entry Guard Timer for STAY Mode expires 
or the system is disarmed. If the alarm is not reset 
before Entry Guard Timer for STAY Mode expires, 
the strobe, bell, and siren outputs are activated into 
alarm. 
 
Single button arming in STAY Mode 1 
reports as User Code number 16.