Bosch Appliances Home Security System ICP-CC488 User Manual

Page of 118
ICP-CC488 | Installation Guide | 5.0  
System Functions 
EN | 27 
 
 
Bosch Security Systems, Inc. | 12/08 | F01U089457-02 
 
5.2 
Master Code Functions 
Master Code functions allow those users that have 
the appropriate priority level to perform certain 
supervisory level functions. You can use these 
functions only when the system is disarmed. 
 
The default Master Code (User Code 1) is 
2580. It is possible to program multiple 
Master Codes. Refer to Section 13.3 
User Code Priority
 for more information. 
To access a Master Code function, enter the Master 
Code and press the corresponding function digit and 
the [AWAY] button. The Master Code functions are 
listed in Table 26
Table 26:  Master Code Functions 
 
Function 
Description 
Arm or disarm both areas at the same time 
(Refer to Section 5.2.1
Add, change, and delete User 
Codes/Remote Radio User Codes 
(Sections 5.2.2 and 5.2.3
Change domestic phone numbers 
(Section 5.2.4
Change Telco Arm/Disarm Sequence 
(Section 5.2.5
Set zones for STAY Mode 2  
(Section 5.2.6
Turn outputs on and off 
(Section 5.2.7
Set the date and time 
(Section 5.2.8
Walk Test Mode 
(Section 5.2.9
Event Memory Recall Mode 
(Section 5.2.10
5.2.1 
Arm or Disarm Both Areas at the Same 
Time 
This Master Code function only operates with 
partitioned ICP-CC488 systems and allows Master 
Codes allocated to both Area 1 and Area 2 to arm or 
disarm both areas at the same time.  
This feature allows a Master Code holder to arm or 
disarm the system by pressing one extra button 
rather than entering a code twice. You can use either 
the CP5 Area Addressable Codepad (CP500A) or the 
Master Partitioned Codepad (CP500P) with this 
function. To enable this feature, select Option 2 in 
Location 501 (refer to Section 19.3.2 Partitioning 
Options 2
). 
To arm or disarm both areas at the same time: 
Enter your Master Code and press [0][AWAY]. Two 
beeps sound and both areas are armed or disarmed 
from AWAY Mode. 
5.2.2 
Changing and Deleting User Codes 
This function allows a Master Code holder to change 
or delete a User Code. 
When using a partitioned ICP-CC488 Control Panel, 
the Master Code holder cannot add, change, or 
delete User Codes unless the User Code is allocated 
to the same area as the Master Code. Refer to Section 
13.3 User Code Priority
 for more information. 
1.  Enter your Master Code and press [1][AWAY]. 
Three beeps sound and the STAY and AWAY 
indicators flash. 
2.  Enter the number of the code (1 to 8) you want 
to change and press [AWAY].  
Two beeps sound and the corresponding zone 
indicator lights. Refer to Table 27 on page 28
3.  Enter the new code and press [AWAY].   
Two beeps sound and the STAY and AWAY 
indicators are extinguished. 
4.  Repeat this procedure to change other User 
Codes. 
 
This function is automatically terminated if 
you do not press a button within 60 sec 
or if you press [AWAY].  
One long beep indicates that the code 
already exists or you entered an incorrect 
user number. 
Example 
To program User Code number 2 as 4627, enter: 
[2 5 8 0 1][AWAY][2][AWAY][4 6 2 7][AWAY]
 
To delete a User Code: 
1.  Enter your Master Code and press [1][AWAY]. 
Three beeps sound and the STAY and AWAY 
indicators flash. 
2.  Enter the number of the code (1 to 8) you want 
to delete and press [AWAY].  
Two beeps sound and the corresponding zone 
indicator lights. Refer to Table 27
3.  Press [STAY] to delete the User Code. 
Two beeps sound and the STAY and AWAY 
indicators are extinguished. 
4.  Repeat this procedure to delete other User 
Codes. 
 
This function terminates automatically if 
you do not press a button within 60 sec 
or if you press [AWAY].  
One long beep indicates that the code 
already exists or that you entered an 
incorrect user number.