Bosch Appliances Home Security System ICP-CC488 User Manual

Page of 118
ICP-CC488 | Installation Guide | 5.0  
System Functions 
EN | 31 
 
 
Bosch Security Systems, Inc. | 12/08 | F01U089457-02 
 
Example 
If Output 2 is programmed as 291000 in Locations 
443 to 448, the Master Code holder can turn on this 
output by entering: 
[2 5 8 0 5][AWAY][2][AWAY][AWAY] 
To turn an output off from the remote codepad: 
1.  Enter your Master Code and press [5][AWAY]. 
Three beeps sound and the STAY and AWAY 
indicators flash. 
2.  Enter the number of the output (1 to 3) and press 
[STAY]. 
Two beeps sound and the output turns off.  
3.  Repeat Step 2 to turn off another output. 
4.  Press [AWAY] button to exit from this function. 
Two beeps sound and the STAY and AWAY 
indicators are extinguished. 
Example 
If Output 2 is programmed as 291000 in Locations 
442 to 447, the Master Code holder can turn off this 
output by entering: 
[2 5 8 0 5][AWAY][2][STAY][AWAY] 
5.2.8 
Setting the Date and Time 
Use this function when the date and time must be 
changed or if the system was powered down.   
If the date and time is not set, the date and time fault 
appears only when the Auto Arming Time is 
programmed in Locations 482 to 485 (refer to Section 
17.12 Auto Arming Time 
on page 79), or when you 
enter Fault Analysis Mode by holding down [5].  
To set the new date and time: 
1.  Enter your Master Code and press [6][AWAY]. 
Three beeps sound and the STAY and AWAY 
indicators flash. 
2.  Enter the day, month, year, hour, and minute in 
DD, MM, YY, HH, MM format (where DD is 
the day of the month, MM is the month of the 
year, YY is the year, HH is the hour of the day, 
and MM is the minute of the day) and press 
[AWAY]. 
Use 24:00 hour format when programming the 
hour of the day. 
Two beeps sound and the STAY and AWAY 
indicators are extinguished. If a long beep 
sounds, an error occurred when you entered the 
date and time. 
Example 
To set the date and time for 1st January 2009 at 
10:30 PM, enter: 
[2 5 8 0 6][AWAY][0 1 0 1 0 9 2 2 3 0][AWAY] 
5.2.9 
Walk Test Mode 
Walk Test Mode allows you to test detection devices 
to ensure that they are functioning correctly. Before 
activating Walk Test Mode, isolate any zones that are 
not required for testing. Refer to Section 3.11 Isolating 
Zones
 for more information. Use Locations 383 and 
384 to enable Walk Test Mode Reports (refer to 
Section 15.2). 
To enter Walk Test Mode: 
1.  Enter your Master Code and press [7][AWAY]. 
Three beeps sound and the STAY and AWAY 
indicators flash. The codepad beeps once per sec 
when Walk Test Mode is active. 
2.  Unseal and seal the zones to be tested.  
The codepad sounds one long beep and the horn 
speaker sounds one short beep each time a zone 
is sealed or unsealed. 
3.  Press [AWAY] to exit from this function.  
Two beeps sound and the STAY and AWAY 
indicators are extinguished. The system returns 
to the disarmed state. 
5.2.10 
Event Non-volatile Memory Recall Mode 
This function allows you to play back the last 40 
system events that occurred. Event Non-volatile 
Memory Recall Mode reports all alarms and each 
arming or disarming of the system and helps with 
troubleshooting system faults. The events are shown 
using the codepad indicators. The event memory is 
not lost even with the power supply off. 
To enter Event Memory Recall Mode: 
Enter your Master Code and press [8][AWAY]. 
Three beeps sound. The events are played back by 
the codepad indicators in reverse chronological 
order. 
Example 
If the events occurred in the following order: 
Table 32:  Event Sequence 
 
Sequence 
Event 
System armed in AWAY Mode 
2 Alarm 
in 
Zone 
3 Alarm 
in 
Zone 
4 System 
disarmed