Bosch Appliances Home Security System ICP-CC488 User Manual

Page of 118
ICP-CC488 | Installation Guide | 7.0  
Programming 
EN | 39 
 
 
Bosch Security Systems, Inc. | 12/08 | F01U089457-02 
 
Example (Auto Step Enabled) 
To enter the Primary Telephone Number 02 (pause) 
9672 1055 when auto step is enabled: 
1.  Press [0 #].  
You are positioned at Location 000 (the Primary 
Telephone Number for Receiver 1). 
2.  Program the number by pressing: 
[10 * 2 * 13 * 9 * 6 * 7 *  2 * 1 * 10 * 5 * 5 * 0*] 
Example (Auto Step Disabled) 
To enter the Primary Telephone Number 02 (pause) 
9672 1055 when auto step is disabled: 
Press [0 #].  
You are positioned at Location 000 (the Primary 
Telephone Number for Receiver 1). 
To program the number, press: 
[10 * # 2 * # 13 * # 9 * # 6 * # 7 * # 2 * # 1 * # 10 * 
# 5 * # 5 * # 0 *] 
 
 
 
 
 
Table 37:  Command 965 Defaults 
 
Location 
Description 
Default Value 
Setting 
032 
Handshake Tone for Receiver 1 
1  
(Handshake Tone) 
033 Transmission 
Format 
4  
(Domestic) 
034 and 039 
Subscriber ID Number 
0, 0, 0, 0, 0, 1 (1 
Beep) 
392 
Zone Status Reporting Options 
(Receiver 2 only) 
401 to 402 
Open/Close Reports 
11, 12 (Open/Close 
Reports) 
403 Open/Close 
Reporting 
Options 
(Receiver 2 only) 
424 to 426 
System Status – Access Denied 
6, 7, 12 (Access 
Denied) 
427 System 
Status 
Reporting 
Options 
(Receiver 2 only) 
428 to 434 
Test Report Time 
0, 0, 0, 0, 7, 1, 0 (Test 
Reports) 
435 Test 
Reporting 
Dialer 
Options 
(Receiver 1 only) 
7.4.9 
Command 999 – Display the Panel 
Type or Software Version Number 
When using the remote codepad, this command 
displays the version of the control panel. Visually 
determining which control panel your printed circuit 
board (PCB) is set to is difficult because various 
control panels use the same PCB.   
The codepad displays 8 to indicate the control panel 
software, ICP-CC488. 
To display the control panel type or software 
version number: 
1.  Enter the Installer Code (the default is 1234) and 
press [#] to enter Installer’s Programming Mode. 
If you are using the remote codepad, the STAY 
and AWAY indicators flash to indicate you 
entered Installer’s Programming Mode.  
2.  Enter [9 9 9 #]. 
Two beeps sound. 
If you are using the remote codepad, the 
codepad lights a zone indicator corresponding to 
the control panel type. Refer to Section 2.0 
Codepad Indicators 
on page 10 for more 
information. 
3.  Press [#] to exit from this command and return 
to the Installer’s Programming Mode. 
4.  Enter [9 6 0 #] to exit from Installer's 
Programming Mode. 
Two sound and the system returns to the 
disarmed state. 
If you are using the remote codepad, the STAY 
and AWAY indicators are extinguished to 
indicate the system is disarmed. 
7.5 
Disable Factory Defaults 
Location 
900 
Default 
This feature prevents the control panel from 
manually restoring the default settings by the default 
button and prevents the use of a programming key to 
automatically download to the control panel when 
the system is disarmed.  
Enter the default setting of 0 for Location 900 to 
restore the control panel to its default settings. Enter 
15 for Location 900 to restrict the ability to restore 
the control panel to its default settings and to require 
the Installer Code for future control panel 
programming.  
If the Installer Code is unknown, you must restore 
the control panel to your Bosch distributor for 
exchange. A nominal fee applies for this service. 
 
The use of this feature is not 
recommended.