ICP-CC488 | Installation Guide | 15.0  
System Reporting Information 
EN | 66 
 
 
Bosch Security Systems, Inc. | 12/08 | F01U089457-02 
 
A Sensor Trouble Restore Report is sent for Burglary 
Zones when the zone is resealed or the next time the 
system is disarmed (whichever happens first). A 24-
Hour Zone sends a restore signal only when it is 
resealed.  
The Trouble code parameter has no effect on 
Contact ID Format because a Sensor Trouble Report 
is always reported as Event Code 380. 
 
If Sensor Trouble Reports are not 
required, program Locations 387 and 388 
as 0. 
 
15.5  Zone Status – Sensor Watch 
Reports 
Location 
389 to 390 
 Location 
Default
Sensor Watch Report 
389 
Sensor Watch Restore Report 
390 5 
A Self Test Failure Report (Contact ID Event Code 
307) is sent to the base station receiver when a zone 
was not activated during the Sensor Watch Time 
programmed in Locations 476 and 477 (refer to 
Section 15.5 Zone Status – Sensor Watch Reports on 
page 78). This report continues to be sent (according 
to the frequency of the Sensor Watch Time) until the 
fault is corrected.  
To clear the fault and stop any additional reporting, 
you must unseal and reseal the zone that registered 
the fault. Use the Sensor Watch Time in Locations 
476 and 477 to set the number of days a zone can 
remain sealed without registering a fault. Refer to 
Section 14.3.5 Zone Options 1 on page 61 to select 
zones to be monitored by the Sensor Watch feature. 
 
If Self Test Failure Reports are not 
required, program Locations 389 and 390 
as 0. 
15.6  Zone Status – Alarm Restore Code 
Location 
391 
Default 
14 
If Zone Alarm Restore Reports are required, 
program this location as 14. If not, program this 
location as 0. 
Location 392 (Section 15.7 Zone Status Reporting Options 
on page 66) is ignored when programming the Alarm 
Restore code and is global for all zones. A zone 
Restore Report is sent only to the receiving party to 
which the zone is allocated (for example, Receiver 1 
or Receiver 2). 
 
 
 
15.7  Zone Status Reporting Options 
Location
392 
No zone status reports allowed 
Report to Receiver 1 
Report to Receiver 2 
Report to both Receiver 1 and Receiver 2 
Report to Receiver 2 only if Receiver 1 fails 
This location is set by default to report only to 
Receiver 1. You can select whether Zone Status 
Reports are sent to Receiver 1, Receiver 2, or both, 
Receiver 2 only when Receiver 1 fails, or no 
reporting. 
For a partitioned ICP-CC488 Control Panel, this 
location is ignored if Option 1 is selected in Location 
501 (refer to Section 19.3.2 Partitioning Options 2 on 
page 85). 
15.8  RF Supervision Time 
Location
393 
Default 
Disable RF Supervision Time Reports 
1 to 15 
Increments of 6 hours (0 to 90 hours) 
An RF Supervision Failure Report (Contact ID Event 
Code 307) is sent to the base station receiver when 
the wireless receiver has not received a signal from 
any RF wireless zone during the RF Supervision 
Time. This report continues to be sent (according to 
the frequency of the RF Supervision Time) until the 
fault is corrected.  
To clear the fault and stop additional reporting: 
Unseal and reseal the zone that registered the fault. 
Refer to Section 3.13 Fault Descriptions on page 18 for 
more information. 
 
If RF Supervision Failure Reports are not 
required, program Location 393 as 0. 
15.9  RF Low Battery Report 
Location
394 to 395 
 Location 
Default 
RF Low Battery Report 
394 
RF Low Battery Restore Report 
395 8 
An RF Low Battery Report (Contact ID Event Code 
384) is sent to the base station receiver when the 
battery voltage on a wireless zone falls below 
approximately 2.4 VDC. An RF Low Battery Restore 
Report is sent on the first valid signal after the 
battery is replaced. 
15.10  RF Receiver Trouble Report 
Location
396 to 397 
 Location 
Default 
Tens digit 
396 
Units digit 
397 9