Programmable Outputs 
EN | 73 
 
 
Bosch Security Systems, Inc. | 12/08 | F01U089457-02 
 
1,7 Sensor 
Watch 
Alarm 
This output operates when the Sensor Watch Count 
is reached. Refer to Section 14.3.5 Zone Options 1 on 
page 61 for more information on programming zones 
for sensor watch. Refer to Section 15.5 Zone Status – 
Sensor Watch Reports on page 78 for setting the 
number of days before a zone registers as a faulty 
sensor watch zone. 
1,8 
Codepad Medical Alarm 
This output operates when a user activates a 
Codepad Medical Alarm by pressing [7] and [9] at 
the same time on the remote codepad. This output is 
reset when a valid User Code is entered at the 
remote codepad. 
1,9 Codepad 
Fire 
Alarm 
This output operates when a user activates a 
Codepad Medical Alarm by pressing [4] and [6] at 
the same time on the remote codepad. This output is 
reset when a valid User Code is entered at the 
remote codepad. 
1,10 
Codepad Panic Alarm 
This output operates when a user activates a 
Codepad Panic Alarm (audible or silent) by pressing 
either [1] and [3] or [STAY] and [AWAY] at the 
same time on the remote codepad. This output is 
reset when a valid User Code is entered at the 
remote codepad. 
1,11 Codepad 
Duress 
Alarm 
This output operates when a user activates a Duress 
Alarm by adding a 9 to the end of the User Code 
used to disarm the system. This output is reset the 
next time the system is armed. 
1,12  
Codepad Tamper – Access Denied 
This output operates when the wrong code is entered 
more times than allowed. The number of incorrect 
attempts allowed is programmed in Location 424 
(refer to Section 15.26 System Status – Access Denied on 
page 69). This output is reset when a valid User Code 
is entered. 
1,13  
Speaker Beeps 
This output functions during all remote radio or 
keyswitch operations, which allows you to install a 12 
VDC buzzer or light as a status indicator. The 
identification beeps are defined in Table 55
Table 55:  Horn Speaker Beeps 
 
No of Beeps 
System Status 
1 System 
disarmed 
System armed in AWAY Mode 
System armed in STAY Mode 1 
1,14 
Horn Speaker (Output 1 Only) 
This output operates only on Output 1. Use this 
output for one or two 8 Ω horn speakers. Refer to 
Section 17.9 Siren Run Time and Section 17.10 Siren 
Sound Rate
 to program the speaker. 
To enable monitoring of the horn speaker, select 
Option 2 in Location 492 (refer to Section 18.1 System 
Options 1 
on page 80).  
1,15  
Sirens Running 
This output operates for the duration of the Siren 
Run Time programmed in Location 479 (refer to 
Section 17.9 Siren Run Time). When the sirens are 
activated, this output is reset when the Siren Run 
Time expires. The relay output (Output 4) is set by 
default for this operation. 
2,0 Strobe 
Operating 
This output operates when an alarm occurs and is 
reset when a valid User Code is entered. The strobe 
output (Output 3) is set by default for strobe 
operation and is programmed to reset automatically 
after 8 hours. 
2,1 Silent 
Alarm 
This output operates when any zone programmed to 
be silent activates. The output is reset when the Siren 
Run Time expires, an audible alarm is activated, or a 
valid User Code is entered. 
2,2 
Alarm When in STAY Mode 
This output operates when an audible or silent alarm 
zone is activated when the system is armed in STAY 
Mode 1 or STAY Mode 2. The output is reset when 
the system is disarmed.  
2,3 
Alarm When in AWAY Mode 
This output operates when an audible or silent zone 
alarm is activated when the system is armed in 
AWAY Mode. The output is reset when the system is 
disarmed. 
2,4 Mimic 
System 
Fault 
This output operates without time delays when any 
system fault occurs, including an AC MAINS supply 
failure. The output is reset when the system fault or 
the AC MAINS supply is restored.  
2,5 
Fire Alarm Resetting 
This output operates when a 24-Hour Fire Zone is 
activated. The output is reset when a valid User 
Code is entered or when Siren Run Time expires. 
2,6 
Fire Alarm Latching 
This output operates when a 24-Hour Fire Zone is 
activated and is reset when the system is armed or 
disarmed.