ICP-CC488 | Installation Guide | 22.0  
Terminals and Descriptions 
EN | 97 
 
 
Bosch Security Systems, Inc. | 12/08 | F01U089457-02 
 
 
Figure 25:  DSRF Radio Receiver Wiring Diagram 
 
1 – ICP-CC488 Control Panel 
2 – DSRF Receiver 
 
Wiring and Power Up 
1.  Remove power from the control panel. 
2.  Connect the RF Receiver to the control panel as 
shown in Figure 25 on page 97.  
Use 0.8 mm (22 gauge) or larger wire. Wire 
length must not exceed 300 m (1000 ft). 
3.  Apply power to the control panel. 
The red LED in the centre of the module lights. 
Operation 
The LED shows the status of the DSRF RF 
Receiver: 
•  LED On – the module is functioning normally. 
•  LED Off – a power failure occurred or the 
module is not wired correctly. 
•  LED turns off momentarily – the module 
acknowledged receiving an RF signal from a 
remote RF device. 
 
 
Figure 26: 
Telecom Connection Diagram for Australia 
   
 
   
 
   
 
   
1
   
 
   
2
   
 
   
3
   
 
   
9
 
7
   
 
  
4
   
 
   
5
  
6
  
 
 
10
 
2
  
3
   
 
   
9
  
7
   
 
   
8
 
1 –  Control panel 
2 –  Red wire 
3 –  Yellow wire 
4 –  6P4C plug (top view) 
5 –  605 plug 
6 –  Internal phones 
7 –  Green wire 
8 –  Telecom line 
9 –  Black wire 
10 –  611 socket 
1 (green): internal phone line 
2 (black): telecom line (street) 
3 and 4: not connected 
5 (yellow): internal phone line 
6 (red): telecom line (street)