Bosch Appliances Home Security System 8500 User Manual

Page of 104
User Priority Access Table
EN | 39
is shipped from the factory. Once a user is logged into the system, the password can 
be changed using the keyboard (see User Function number 10). Refer to the specific 
section of the operation instructions for exact procedures of using keyboard User 
Functions. Although the table indicates 32 possible users, only eight (8) keyboards 
are supported in LTC 8500 Series systems.
14.2 User Priority Access Table
The following table shows system function access as it applies to the eight (8) levels 
of users.
Priority Level
System Function 
1
2 to 7
Switch video on monitors Yes Yes 
Yes
Control pan/tilt/zoom camera Yes 
Yes Yes
Lock monitor 
Yes Yes 
Yes
Lock pan/tilt/zoom camera
Yes 
Yes Yes
Acknowledge alarms Yes Yes 
Yes
Perform keyboard test
Yes
Yes
Yes
Show keyboard number
Yes
Yes
Yes
Activate keyboard beeper
Yes
Yes
Yes
Change user password
Yes
Yes
Yes
Program sequences
Yes 
Yes 
No
Position video overlay display Yes 
Yes No
Set overlay display brightness
Yes
Yes
No
Select overlay display type 
Yes 
Yes 
No
Set system time/date 
Yes 
Yes 
No
Program pre-positions
Yes
Yes
No
Set time/date format
Yes
No
No
Set camera and monitor titles Yes No 
No
Enable time events
Yes
No
No
Reset system
Yes
No
No
Printout tables and sequences
Yes
No
No
Default monitor overlay
Yes
No
No
Select alarm response mode
Yes 
No 
No
Select printer mode
Yes
No
No
Designate alarm monitor type
Yes
No
No
Select keyboard log-in
Yes
No
No
Select console log-in
Yes
No
No
Configure/reset RS-232 ports
Yes 
No
No