White Rodgers 50M56U-751 Replacement Kit for Carrier Single Stage Integrated Furnace Control System Diagnostic LED with Fault Recall Installation Instruction

Page of 8
The 50M56U-751 kit is a Single Stage HSI Integrated Furnace 
Control kit for Carrier. This kit replaces the following Carrier 
controls:
Carrier
White-Rodgers
HK42FZ004
HK42FZ009
HK42FZ016
50M56-751
HK42FZ007
HK42FZ011
HK42FZ034
HK42FZ008
HK42FZ013
325878-751*
*Universal replacement for all Carrier controls.
 
The control employs a microprocessor to continually monitor, 
analyze, and control the proper operation of the gas burner, 
inducer, and fan.
Twinning: The control board in this Kit CANNOT be twinned 
with any of the Carrier circuit boards.
50M56U-751
Carrier Single Stage
HSI Integrated Furnace Control Kit
INSTALLATION INSTRUCTIONS
 
 DESCRIPTION
Installation should be done by a qualified heating and air 
conditioning contractor or licensed electrician.
If in doubt about whether your wiring is millivolt, line, or low 
voltage, have it inspected by a qualified heating and air 
conditioning contractor or licensed electrician.
Do not exceed the specification ratings.
All wiring must conform to local and national electrical codes 
and ordinances.
This control is a precision instrument, and should be handled 
carefully. Rough handling or distorting components could 
cause the control to malfunction.
Following installation or replacement, follow manufacturer’s 
recommended installation/service instructions to ensure 
proper operation.
 
 PRECAUTIONS
Do not short out terminals on gas valve or primary 
control. Short or incorrect wiring may damage the 
thermostat.
CAUTION
!
Failure to comply with the following warnings could result 
in personal injury or property damage.
FIRE HAZARD
•  Do not exceed the specified voltage.
•  Replace existing control with exact model and
dash number.
•  Protect the control from direct contact with water
(dripping, spraying, rain, etc.).
•  If the control has been in direct contact with
water, replace the control.
•  Label all wires before disconnection when
servicing controls. Wiring errors can cause 
improper and dangerous operation.
•  Route and secure wiring away from flame.
SHOCK HAZARD
•  Disconnect electric power before servicing.
•  Ensure proper earth grounding of appliance.
•  Ensure proper connection of line neutral and line
hot wires.
EXPLOSION HAZARD
•  Shut off main gas to appliance until installation
is complete.
WARNING
!
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE 
INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL 
INJURY AND/OR PROPERTY DAMAGE.
PART NO. 37-7513B
Replaces 37-7513A
1421
www.white-rodgers.com
www.emersonclimate.com
50M56-751
The kit contains:
1 – 50M56-751 ignition control board
1 – Set of interconnect harnesses
1 – Manual
1 – Bag of accessories