D9412GV3/D7412GV3 | Program Entry Guide | 4.0  Schedules (Skeds) 
EN | 118 
 
 
Bosch Security Systems, Inc. | 10/11 | F01U170807-02 
 
Default: 
Selection: 
0 to 24, 28, 29 
 
 
 
  S## Cmd Center 
 
Default: Blank (0) 
Selections: Blank (0), 1 to 8
 
Blank 
(0) 
No keypad is 
specified for 
Custom Function 
activation. 
Identify the specific keypad 
(CC #) where the Custom 
Function is entered. Only one 
keypad can be assigned for 
this sked function. 
1 to 8 
Command center 
(keypad) address 
specified for 
Custom Function 
activation. 
 
 
 
  S## Custom Func 
 
Default: Blank (0) 
Blank 
(0) 
No Custom 
Function is 
activated. 
11 
Execute Custom Func: This 
function emulates any of the custom 
functions assigned to the keypad 
that can be executed by a user from 
the keypad. When a sked executes 
a custom function, it is subject to 
the scope of the selected keypad. 
Cmd Center and Custom Func 
prompts appear after entering 
Function Code 11. Both entries are 
required. 
Selections: Blank (0),  
128 to 143 for D9412GV3,  
128 to 131 for D7412GV3
 
Enter the custom function this 
sked executes. 
128 to 
143 
Custom Function 
to activate. 
12 Contact 
RPS: This function 
attempts to contact an Unattended 
RPS at the configured time. The 
control panel’s account in RPS 
controls the operations performed 
upon successful contact. 
 
 
Avoid having multiple functions occur at the same time at the same address. Functions can clash 
and the effect on the control panel is unpredictable. 
 
 
Ensure that the Custom Function being executed or any of the commands nested inside the 
Custom Function are not passcode protected. 
 
 
Do not program multiple skeds to execute at the same keypad during the same time. 
Do not program skeds to execute at times when a user is likely to be executing functions at the 
keypad. If it is necessary to do so, there are two ways to work around the situation: 
1.  For a D1255 keypad type, program "C","C"at the beginning of the Custom Function Key 
Strokes entry. This aborts the user’s function and allows the sked to execute. 
2.  Program the sked to execute at an address (Cmd Center) with no keypad physically attached to 
it. The CC # must be assigned to an area and have the appropriate scope programmed. 
(Continued on next page.)