Bosch Appliances Video Game Controller d9412gv3 User Manual

Page of 154
D9412GV3/D7412GV3 | Program Entry Guide | 4.0  Schedules (Skeds) 
EN | 121 
 
 
Bosch Security Systems, Inc. | 10/11 | F01U170807-02 
 
Default: 
Selection:  0 to 24, 28, 29 
 
 
 
  S## Door 1 [through 8] 
 
Default: No 
Selection: Yes or No
 
Yes 
Disable the 
sending of Access 
Granted Events 
for Door #. 
22 
Access Authority Events 
Off:
 The control panel can log 
Access Granted Events when 
a valid token, RTE, REX, or 
Unlock Door Event is detected 
for a specific door. These 
events can be directed to print 
at a local printer or send a 
report remotely through phone 
routing. This sked disables 
Access Granted Events to be 
reported for Door #. 
This parameter disables the sending 
of Access Granted Events for Door #. 
No 
Do not disable the 
sending of Access 
Granted Events 
for Door #. 
 
 
 
  S## Door 1 [through 8] 
 
Default: No 
Yes 
Enable the 
sending of No 
Entry Events for 
Door #. 
23 
No Entry Events On: The 
control panel can log No Entry 
Events when an invalid token 
is detected for a specific door. 
No Entry Events include No 
Entry-Secured, No Entry-
Interlock, No Entry-Unknown 
ID, and No Entry-Level. These 
events can be directed to print 
at a local printer or send a 
report remotely through phone 
routing. This sked enables No 
Entry Events to be reported for 
Door #. 
Selection: Yes or No 
This parameter enables the sending 
of No Entry Events for Door #. 
No 
Do not enable the 
sending of No 
Entry Events for 
Door #. 
 
 
 
  S## Door 1 [through 8] 
 
Default: No 
Yes 
Enable the 
reporting of No 
Entry Events for 
Door #. 
24 
No Entry Events Off: The 
control panel can log No Entry 
Events when an invalid token 
is detected for a specific door. 
No Entry Events include No 
Entry-Secured, No Entry-
Interlock, No Entry-Unknown 
ID, and No Entry-Level. These 
events can be directed to print 
at a local printer or send a 
report remotely through phone 
routing. This sked disables No 
Entry Events to be reported for 
Door #. 
Selection: Yes or No 
This parameter disables the sending 
of No Entry Events for Door #. 
No 
Do not enable the 
reporting of No 
Entry Events for 
Door #. 
28 
Expanded Off-Normal Test Report: To generate this event, one or more points must be in an off-
normal state at the time the sked executes. In addition, any system trouble that is active also 
generates an Expanded Off-Normal Test Report. Expanded Off-Normal Test Reports include the Off 
Normal Test Report Event as well as the supplementary event at the time the report is generated. 
The Event Log shows only a Test Report Event. 
If none of these conditions exists at the time the sked executes, only a Sked Executed Event is 
generated and the Off-Normal Test Report is not sent.