EN | 126 
 
 
Bosch Security Systems, Inc. | 10/11 | F01U170807-02 
 
Status Rate 
Default: 
Selection: 
0 to 255 
Status information is sent only when 
requested. 
1 to 255 
Status information is sent at the 
interval programmed. 
 
 
If the Status Rate is set to a value less 
than 10, and 1 to 6 SDI devices are 
connected to the system, the fastest the 
control panel can send the status 
information is in approximately 1 sec. If 
more than six SDI devices are connected 
to the control panel, the fastest the 
control panel can send the information is 
in approximately 1.5 sec to 2 sec. 
This item determines how often the default status 
information is sent to the serial interface module 
(SIM). The status information includes: 
  The current point status (normal or off-normal),  
  The control panel’s area status (Master Armed, 
Master Instant Armed, Perimeter Delay Armed, 
Perimeter Instant Armed, Disarmed, Area Entry 
Delay, Perimeter Entry Delay, Area Exit Delay, 
and Perimeter Exit Delay) 
  The control panel status (AC Fail, Battery 
Missing, AC Restore, Battery Low, and so on) 
  Relay status (relay on or relay off) 
Entries are in 100 millisecond increments. If a 5 is 
entered, the status information is sent every 500 
milliseconds (or 0.5 sec). An entry of 10 equals 1 sec. 
 
5.4 SDI 
RPS 
Parameters 
Configure remote programming software (RPS) 
parameters when communicating over a private local-
area network (LAN), wide-area network (WAN), or 
general packet radio system (GPRS). To allow RPS 
to communicate with a control panel over a LAN or 
WAN, an SDI-Ethernet network interface module 
(NIM) and RPS (version 5.13 or higher) are required. 
The computer on which RPS is installed needs a 
network card. See your information systems 
administrator for network requirements. 
This section allows you to:  
  Provide for local programming by a DX4010V2 
Serial Interface Module. 
  Provide remote programming by a Conettix 
DX4020 Network Interface Module or an 
ITS-DX4020-G. 
  Provide enhanced route paths for event reporting 
through a network using a Conettix DX4020 
Network Interface Module or an ITS-DX4020-G. 
Although not listed in this section, RPS checks for the 
RPS passcode (refer to Section 2.6 RPS Parameters 
on page 32), Datalock Code, and control panel type 
to determine if this RPS session should continue.