D9412GV3/D7412GV3 | Program Entry Guide | 5.0  AUXPARM 
EN | 131 
 
 
Bosch Security Systems, Inc. | 10/11 | F01U170807-02 
 
5.5 
Programming Path Numbers and 
IP Addresses for Enhanced 
Communications 
Enhanced communications is the ability to 
communicate by some means other than the 
standard digital dialer. In this section, programmable 
parameters allow you to define up to four separate 
enhanced communication paths to which events can 
be routed. To route an event (such as an Alarm or 
Trouble) to an enhanced communication path, 
additional programming must also be completed in 
Section  2.3 Routing on page 17
Enhanced Comm 
Default: 
No 
Selection: 
Yes or No 
Yes 
Enable enhanced communications 
over the SDI bus. 
No 
Do not enable enhanced 
communications over the SDI bus. 
 
 
If using IP Addresses as the 
communication means for UL 864 
Commercial Fire applications, set this 
parameter to Yes
Determines if the control panel allows enhanced 
communications over the SDI bus.  
Events can be routed to as many as four available 
enhanced communication paths through the SDI bus. 
If an event (or group of events) is routed to an SDI 
path, the number entered in Primary Device 
determines which SDI path is used (provided that 
RG# PrimPrimary SDI was set to Yes in Routing). 
If events are to be routed to an IP address (in a 
private LAN or WAN application), determine which 
path is used (Path 1 to Path 4), and enter the 
appropriate IP Address for that path (refer to Path # 
IP Address 
on page 131). 
If events are to be routed to an SDI Path but not to an 
IP Address, allow the setting for Path # IP Address 
to remain at 0. Path # Poll RatePath # Ack Wait
and Path # Retry Count must be programmed. 
Keypad Programming to Enable or Disable 
Enhanced Comm 
D1255 
1.  Refer to Figure 1 on page 7 to access Keypad 
Programming and navigate to the ENHANCED 
COMM 
option. Press [ENT]. 
2.  The keypad shows the current setting by 
alternating between COMMUNICATIONS> and 
ENHANCED> YES or NO. To configure 
enhanced communications, press [ENT]. 
3.  Press [NEXT] or [PREV] to toggle to YES to 
enable enhanced communication or No to disable 
enhanced communication, and then press [ENT].  
When the keypad reads PARAMETER SAVED, your 
selection has been configured.  
D1260 
1.  Refer to Figure 2 on page 8 to access Keypad 
Programming and navigate to the Enhanced 
Comm 
option. Press the Enhanced Comm 
softkey. 
2.  The current Enhanced Enabled configuration 
shows (for example, Enhanced Enabled: Yes). 
3.  Press the Edit softkey to change the 
configuration. 
4.  Press the Yes or No softkey, and then press the 
Save softkey to save the changes. 
When the keypad reads Parameter Saved, your 
selection is configured. 
Path # IP Address 
Default: 
0.0.0.0  
Selection: 
0.0.0.0 to 255.255.255.255 
0 to 
255 
There are four numbers in a valid IP 
address. Leading zeros are not required. 
 
If using IP Addresses as the 
communication means for UL 864 
Commercial Fire applications, set Path 
# IP Address
 as necessary. 
 
Path # IP Address contains the IP addresses for each 
of the four enhanced communication paths available.  
An IP address has four fields. Each field has a range 
of 0 to 255. For example, an IP address is expressed 
as 110.227.64.190. Contact your network 
administrator to obtain the appropriate IP Address to 
contact a central station receiver. 
Refer to Keypad Programming of Path # IP Address, 
Path # Port Number, and Path # Poll Rate
 on page 
132. 
Path # Port Number 
Default: 
7700 
Selection:  1 to 65535 
This prompt specifies the destinaton port number for 
each of the four enhanced communication route path 
destinations.  
 
Whenever an IP address or port number 
configured in the control panel is 
changed, the central station must 
resynchronize the control panel’s 
anti-replay/anti-substitution static key.