D9412GV3/D7412GV3 | Program Entry Guide | 5.0  AUXPARM 
EN | 138 
 
 
Bosch Security Systems, Inc. | 10/11 | F01U170807-02 
 
For SIA CP-01 Compliance: 
Abort Window
 is a required parameter. 
 
 
To meet UL requirements, the combined 
Entry Delay time and Abort Window time 
must not exceed 60 sec. For Entry Delay 
time programming information, refer to  
P## Entry Delay in the Point Responses 
section of your control panel’s program 
entry guide. 
UL note: Maximum settings for 
residential use:  
Exit Delay – 120 sec 
Entry Delay = 45 sec bell 
Off-Premise Transmission = 60 sec 
Maximum settings for commercial use: 
Exit Delay – 120 sec no line security 
Entry Delay = 60 sec bell 
Off-Premise Transmission = 60 sec 
The system must use both the bell and  
off-premise transmission. 
Passcode Length 
Default: 
Selection:  0, 3, 4, 5, or 6 
Sets a variable length for user 
passcodes, allowing for backward 
compatibility 
3, 4, 5, 
or 6 
Sets a fixed length to all user 
passcodes. 
During entry delay, the code is accepted when the 
last digit is pressed to disarm the area.  
For SIA CP-01 Compliance: 
Passcode Length
 must be set to 3, 4, 5, or 6. 
Swinger Count 
Default: 
Selection:  1, 2, 3, or 4 
1, 2 
Number of fault or trouble bypasses 
allowed per hour for SIA CP-01 
compliance. 
Optional fault count 
Value used for backward 
compatibility with previous control 
panel operation. 
When a point has P# Swinger Bypass set to Yes
the value set in Swinger Count determines the 
number of times the point is faulted erroneously 
within an hour before it is automatically bypassed.  
For SIA CP-01 Compliance: 
P## Swinger Bypass
 can be Yes or No. 
If P## Swinger Bypass is YesSwinger Count must 
be 1 or 2. 
Remote Warning 
Default: 
Yes 
Selection:  Yes or No 
Yes 
The system uses the Alarm Bell 
output to annunciate the arming and 
disarming of an area through remote 
software, or a remote arming device 
such as a key switch or key fob. 
No 
No remote warning occurs to 
annunciate the arming and disarming 
of an area through remote software, 
or a remote arming device such as a 
key switch or key fob. 
Upon remote arming, the output pulses on for 2 sec. 
Upon remote disarming, the output pulses on, off, on, 
off for 2 sec each. 
For SIA CP-01 Compliance 
Remote Warning
 must be set to Yes
Crystal Time Adjust 
Default: 
No 
Selection: 
Yes or No 
Yes 
Set the clock time control on the 
control panel to the on-board crystal 
frequency. 
No 
Do not set the clock time control on 
the control panel to the on-board 
crystal frequency. 
When set to Yes, the control panel switches its clock 
time control from the traditional AC frequency to the 
on-board crystal frequency.