Bosch Appliances Video Game Controller d9412gv3 User Manual

Page of 154
D9412GV3/D7412GV3 | Program Entry Guide | 2.0  Panel and Area Wide Parameters 
EN | 15 
 
 
Bosch Security Systems, Inc. | 10/11 | F01U170807-02 
 
 
Table 5:  Modem IIIa
2
 Communication Format 
Data - User ID Numbers 
 
Point/User Flag 
NO 
Point/User Flag 
YES 
000 
000 
001 to 005 
001 to 005 
006 to 013 
601 to 608 
014 to 021 
701 to 708 
022 to 029 
801 to 808 
030 to 037 
B01 to B08 
038 to 045 
C01 to C08 
046 to 053 
D01 to D08 
054 to 061 
E01 to E08 
062 to 069 
F01 to F08 
070 to 249 
000 
 
 
 
Table 6:  Modem IIIa
2
 Communication Format 
Data – Point Numbers 
 
Point/User Flag 
NO 
Point/User Flag 
YES 
001 to 008 
100 to 800 
009 to 024 
101 to 116 
025 to 040 
201 to 216 
041 to 056 
301 to 316 
057 to 072 
401 to 416 
073 to 088 
501 to 516 
089 to 104 
601 to 616 
105 to 120 
701 to 716 
121 to 136 
801 to 816 
153 to 168 
217 to 232 
169 to 184 
317 to 332 
185 to 200 
417 to 432 
201 to 216 
517 to 532 
217 to 232 
617 to 632 
233 to 247 
717 to 731 
 
 
2.2.1 Special 
Point/User 
Reporting 
Independent Zone Control Notice: When using 
Independent Zone Controls (IZC) to send 
Opening/Closing Reports by point, do not duplicate 
reporting independent point numbers with User ID 
Reports (refer to Section 2.1 Passcode or Token 
Worksheet
 on page 82). For example: If an IZC is 
connected to Point 8, do not use User ID 8. 
D6000: Opening/Closing User ID numbers are 
identified at the receiver as zones (same identification 
as independent points). Refer to Table 7
Table 7:  D6000 User IDs and Zones 
 
User ID 
Number 
Zone 
User ID 
Number 
Zone 
91 
2 C 92 2 
93 
4 E 04 4 
95 
6 6 96 0 
 
 
8 8    
DTMF Dialing 
Default: 
Yes 
Selection:  Yes or No 
Yes 
Dials the programmed phone 
number(s) using DTMF. 
No Pulse 
dialing 
only. 
Use dual-tone multi-frequency (DTMF) to dial the 
central station receiver phone number(s) for event 
reports, or to dial the remote programming software 
(RPS).