D9412GV3/D7412GV3 | Program Entry Guide | 2.0  Panel and Area Wide Parameters 
EN | 37 
 
 
Bosch Security Systems, Inc. | 10/11 | F01U170807-02 
 
 
Area 1 must be enabled:  
  System events such as power and 
phone supervision do not send a 
report correctly if Area 1 is disabled. 
  When programmed No, points 
assigned to this area do not generate 
events, show at the keypad when 
arming and disarming, or send status 
reports. All user authority in this area 
is turned off while the area is 
disabled. 
 
 
To meet UL 864 requirements, set A# 
Area On
 to Yes
 
Area# Account Number 
Default: 
0000 
Selection:  For Modem and Contact ID (four-
digit account numbers): 0000 to 
9999,  
BBBB to FFFF 
For Modem (ten-digit account 
numbers): 0000000000 to 
9999999999, BBBBBBBBBB to 
FFFFFFFFFF 
Determines the account number for this area. An 
account number must be assigned to each active 
area. 
Account numbers are used to group areas together. 
Each area can have a different account number, or 
several areas can share the same account number. 
The control panel uses the account number as a 
reference for arming and keypad text displays. 
Contact ID: Only the last four digits are sent.
 
Modem IIIa
2
: Enter a four-digit or ten-digit number. 
Keypad Programming of Area # On and Area# 
Account Number 
D1255 
1.  Refer to Figure 1 on page 7 to access Keypad 
Programming and navigate to the AREA 
PARAMETERS 
option. Press [ENT]. 
2.  The keypad reads AREA NUM 1 – 32 (1 – 8 for 
the D7412GV3). 
3.  Enter the area number you wish to configure and 
press [ENT]. The current area status shows (for 
example, AREA 1 ON: YES). 
4.  Press [ENT] to change the area’s status. 
5.  Press the [PREV] or [NEXT] button to toggle 
between YES and NO, and then press [ENT] 
when the desired configuration option shows. 
When the keypad reads PARAMETER SAVED, your 
selection is configured. 
6.  When the keypad reads AREA STATUS, press 
[NEXT] to advance to the A# ACCOUNT 
NUMBER 
option. The keypad shows the currently 
configured account number.  
7.  Press [ENT] to change the account number. 
8.  The [PREV] button acts as a [Backspace] key. 
The [COMMAND] key cycles though the special 
account number characters (B, C, D, E, F); 
[NEXT] select the account number character. 
Press [PREV] to delete the characters of the 
account number and then enter the new account 
number. 
9.  Press [ENT] to save the changes. 
When the keypad reads Parameter Saved, your 
selection is configured. 
D1260 
1.  Refer to Figure 2 on page 8 to access Keypad 
Programming and navigate to the Area 
Parameters 
option. Press [ENT]. 
2.  The keypad reads Area Number 1 – 8
3.  Enter the area number you wish to configure and 
press [Enter]. The current area status shows (for 
example, Area 1 On: Yes). 
4.  Press the Edit softkey to change the area’s status. 
5.  Press the Yes or No softkey, and then press the 
Save softkey to save the changes. 
When the keypad reads Parameter Saved, your 
selection is configured. 
6.  When the keypad reads Area Status, press the 
Account Number softkey. The keypad shows the 
currently configured account number.  
7.  Press the Edit softkey to change the account 
number. 
8.  Use the softkeys and the number buttons on the 
keypad to enter the new account number. The 
Backspace softkey allows you to erase 
characters. The Clear softkey allows you to clear 
the entire account number. When entering a letter 
character, press the letter's softkey to select it. 
The Previous and Next softkeys advance through 
the letter characters (A, B, C, D, E, F). 
9.  Press the Save softkey to save the changes. 
When the keypad reads Parameter Saved, your 
selection is configured. 
A# Force Arm/Bypass Max 
Default: 
Selection:  0 to 99 
Specify the maximum number of combined Controlled 
points that can be faulted or bypassed when arming 
this area.