Bosch Appliances Video Game Controller d9412gv3 User Manual

Page of 154
D9412GV3/D7412GV3 | Program Entry Guide | 2.0  Panel and Area Wide Parameters 
EN | 45 
 
 
Bosch Security Systems, Inc. | 10/11 | F01U170807-02 
 
A# Area O/C 
Default: 
Yes 
Selection:  Yes or No 
Yes 
Include the Area # and generate Opening 
and Closing Reports for this area when it is 
armed. 
No 
Do not include the Area # or generate 
Opening and Closing Reports for this area. 
Determines if the area number and the account 
number are reported at arming and disarming. As 
long as Account O/C is No, the account number 
sends a report when arming this area individually. If 
Account O/C is Yes, all areas with the same account 
number must also be armed. 
An Area Opening Report is generated when each 
area is opened (disarmed). An Area Closing Report is 
generated when each individual area is closed 
(armed). 
 
Do not program this item as Yes if the 
control panel reports to an automation 
system that cannot interpret multiple Area 
Opening and Closing Reports. 
A# Disable O/C in Window 
Default: 
Yes 
Selection: 
Yes or No 
Yes 
Do not send Opening and Closing Reports 
to the central station if they occur inside an 
active window. 
If an Opening or Closing Report occurs 
outside a window, send it with an early or 
late modifier. Refer to Section 4.1.1 
Opening and Closing
 on page 105. 
The active window must be a Closing 
Window for Closing Reports. It must be an 
Opening Window for Opening Reports. 
No 
Send Opening and Closing Reports to the 
central station even when they occur inside 
a programmed window. If an opening or 
closing occurs outside of the appropriate 
window, it reports but does not have an 
early or late modifier. 
If you want to monitor all opening and 
closing activity and use features provided 
by Opening and Closing Windows, program 
this item as No, and program the 
appropriate O/C Windows. 
Determines if opening and closing activity is reported 
when it occurs inside an Opening or Closing Window, 
as programmed in O/C Windows. 
Reports are always logged and printed on a local 
printer, if installed. 
A# Auto Close 
Default: 
No 
Selection:  Yes or No 
Yes 
The area automatically master arms at the 
end of the Close Window. 
When the area is armed automatically, a 
Closing Report is sent if the Area or 
Account Reports are programmed to do so. 
No 
Do not automatically arm the area at the 
end of the Close Window. 
With this program item, the control panel can 
automatically master arm the area at the end of the 
Closing Window regardless of the previous armed 
state. 
 
When an area master arms automatically 
at the end of a Close window, the system 
disregards the settings in A# Force Arm 
Max
 and P## Bypassable for any faulted 
points. The faulted points arm when they 
return to normal state.  
A# Fail to Open 
Default: 
No 
Selection:  Yes or No 
Yes 
Fail to Open Report is sent for this 
area if the area was not disarmed 
when the Opening Window stop time 
occurred. 
No 
Fail to Open Report is not sent for 
this area. 
Use to determine if a Fail to Open Report is sent for 
this area. This can determine if a user failed to 
disarm the area before the Opening Window expiring. 
Normal Opening and Closing Reports do not need to 
be programmed to use this feature.