D9412GV3/D7412GV3 | Program Entry Guide | 2.0  Panel and Area Wide Parameters 
EN | 54 
 
 
Bosch Security Systems, Inc. | 10/11 | F01U170807-02 
 
 
 
  If a door is not programmed for this 
prompt and a door is not assigned to 
the area using the D# Entry Area in 
the Access Control section, 9210 NOT 
READY appears at this keypad when 
you attempt to add a user. The 
message indicates that the control 
panel cannot start the Add User Mode 
until a door is assigned to this keypad. 
  Assigning a door to a keypad is not 
necessary for the user to control the 
door(s) using the Door Control 
function. Any door that is active can be 
controlled by a user who has the 
appropriate door control authority. The 
door control functions are available to 
a valid user at any keypad with access 
to the area where the door is 
assigned.  
 
 
During the Add User Mode, tokens or 
cards, door control requests, and 
RTE/REX do not function. Put the Door 
Mode into an unlocked state before 
adding users if there is heavy activity for 
this door. 
CC# Trouble Tone 
Default: 
Yes  
Selection:  Yes or No 
Yes 
Panel-wide trouble tones sound and 
visual displays show at this keypad. 
No 
Panel-wide troubles do not sound. 
Visual displays still show. 
Determines whether this keypad, or any keypad with 
the same address setting, emits the panel-wide 
trouble tones (power, phone, SDI bus, and Zonex 
bus). 
 
To meet UL 864 requirements, set CC# 
Trouble Tone
 to Yes
 
 
Panel-wide trouble tones do not include 
Point Troubles, Buzz on Fault, or Close 
Door Now. 
 
 
Assign two CCs to the same area so one 
keypad emits the tone and another does 
not. 
CC# Entry Tone 
Default: 
Yes  
Selection: 
Yes or No 
Yes 
This keypad sounds entry tones. 
No 
This keypad does not sound entry 
tones. 
Determines whether this keypad, or any keypad with 
the same address setting, emits the entry delay tone. 
Any Delay point within the area scope of this keypad 
starts the entry sequence. 
 
This prompt allows you to manage the 
tone by keypad. Entry Tone can also be 
turned off when programming your P## 
Entry Tone
 off in Point Index
 
 
Assign two CCs to the same area so one 
keypad emits the tone and another does 
not. 
For SIA CP-01 Compliance 
CC# Entry Tone
 can be set to Yes or No
CC# Exit Tone 
Default: 
Yes  
Selection: 
Yes or No 
Yes 
This keypad sounds exit tones. 
No 
This keypad does not sound exit 
tones. 
Determines whether this keypad, or any keypad with 
the same address setting, emits the exit delay tone 
during the delay arming of an area(s). Any keypad 
with a scope to arm this area can initiate the exit tone 
sequence. 
This prompt allows you to manage the tone by 
keypad. Exit Tone can also be turned off when 
programming A# Exit Tone in Area Parameters. 
The cadence and pitch of the exit tone increase for 
the last 10 sec of the exit delay time.  
 
This SIA CP-01 required feature is not 
supported on the D720 Series Keypads. 
 
 
Assign two CCs to the same area so one 
keypad emits the tone and another does 
not. Set one keypad for CC EXIT TONE = 
YES, and one to EXIT TONE = NO.