Bosch Appliances Video Game Controller d9412gv3 User Manual

Page of 154
D9412GV3/D7412GV3 | Program Entry Guide | 2.0  Panel and Area Wide Parameters 
EN | 64 
 
 
Bosch Security Systems, Inc. | 10/11 | F01U170807-02 
 
View Log 
Default: 
Selection:  -, E, or P 
 
Function 
No. 
Function Name 
Alternate 
Keystroke 
21 View 
Log 
(Menu function 
only) 
Use this function to view all of the system events, 
their time stamps, User IDs, or point numbers. User 
Name and Point Text are not stored in the event log, 
but they appear when the control panel matches 
them with the User ID ### and the Point ###. 
Each event appears on one line in the log. Any 
information related to that event appears on a 
separate line in the log. 
Because events in the log are not uniform in length, 
the control panel can store from 500 to 1000 events. 
 
Print Log 
Default: 
Selection:  -, E, or P 
 
Function 
No. 
Function Name 
Alternate 
Keystroke 
22 
Print Event Log 
(Menu function 
only) 
Use this function to print all the events stored in the 
control panel beginning at the start date and ending 
with the last event in the log. 
 
User Cmd 7 
Default: 
Selection: 
-, E, or P 
 
Function 
No. 
Function Name 
Alternate 
Keystroke 
23 
User COMMAND 
[COMMAND][7] 
Use this function to activate an alarm programmed in 
COMMAND 7 in the POINTS > Command 7 / 
Command 9 section. 
User Cmd 9 
Default: 
Selection:  -, E, or P 
 
Function 
No. 
Function Name 
Alternate 
Keystroke 
24 
User COMMAND 
[COMMAND][9] 
Use this function to activate an alarm programmed in 
COMMAND 9 in the POINTS > Command 7 / 
Command 9 section. 
Bypass a Point 
Default: 
Selection:  -, E, or P 
 
Function 
No. 
Function Name 
Alternate 
Keystroke 
25 
Bypass a Point 
[COMMAND][0] 
Use this function to bypass individual points that have 
P## Bypassable enabled. Points within the scope of 
the keypad can be bypassed where the function is 
entered (refer to Section 2.9.1 Keypad (Command 
Center) Assignment
) on page 50. 
The control panel ignores alarms and troubles, and 
does not display point faults when a point is 
bypassed. 
Unbypass a Point 
Default: 
Selection: 
-, E, or P 
 
Function 
No. 
Function Name 
Alternate 
Keystroke 
26 
Unbypass a Point [COMMAND][0][0] 
Use this function to unbypass individual points that 
are programmed either P## Force Arm Returnable 
or P## Bypass Returnable. Points within the scope 
of the keypad can be unbypassed where the function 
is entered (refer to Section 2.9.1 Keypad (Command 
Center) Assignment) 
on page 50The control panel 
responds to alarms and troubles, and displays point 
faults when a point is unbypassed.