D9412GV3/D7412GV3 | Program Entry Guide | 2.0  Panel and Area Wide Parameters 
EN | 67 
 
 
Bosch Security Systems, Inc. | 10/11 | F01U170807-02 
 
Keypad Programming of the Keypad Programming 
Option 
D1255 
1.  Refer to Figure 1 on page 7 to access Keypad 
Programming and navigate to the DISABLE KP 
PROG 
option. Press [ENT]. 
2.  The current keypad programming configuration 
shows (for example, ALLOWED: YES). 
3.  Press [ENT] to change the configuration. The 
keypad reads PRG ALLOWED: followed by YES 
or NO. 
4.  Press [NEXT] or [PREV] to toggle to YES to allow 
keypad programming or No to disable keypad 
programming, and then press [ENT] to save the 
changes. 
When the keypad reads PARAMETER SAVED, your 
selection has been configured.  
 
You can continue using the current 
programming session. Keypad 
programming is disabled once you exit 
the current session. 
 
D1260 
1.  Refer to Figure 2 on page 8 to access Keypad 
Programming and navigate to the Disable 
Keypad Prog 
option.  
2.  The current keypad programming configuration 
shows (for example, Keypad Programming 
Allowed: Yes). 
3.  Press the Edit softkey to change the area’s 
status. 
4.  Press the Yes or No softkey, and then press the 
Save softkey to save the changes. 
5.  Press the Save softkey to save the changes. 
6.  When the keypad reads Parameter Saved, your 
selection has been configured. 
 
You can continue using the current 
programming session. Keypad 
programming is disabled once you exit 
the current session. 
 
2.10.6  Authority Level Selections 
Use Section 2.10.6 Authority Level Selections on 
page 66 to determine which Authority Level can 
access keypad functions that are passcode 
protected. Selecting Enable items in the Authority 
Level section is not necessary if the keypad function 
is disabled or enabled. Each individual function has 
two selections you can use for the authority level you 
are programming. 
 
 
 
Table 25: Authority Level Selections 
 
Authority 
Level 
Description 
Disabled: This function is not 
authorized for the user who is 
assigned this authority level. 
Enabled: This function is 
authorized for the user who is 
assigned this authority level. 
 
 
 
Authority Level 
Default: 
Selection:  1 to 14 
Enter the number of the authority level you want to 
program. Authority Level 15 (Service Passcode) 
cannot be edited. 
 
To determine the L## default values on 
pages 67 through 76, refer to the User 
Interface
 section in the program record 
sheet. 
 
L## Disarm 
Default: 
Refer to the program record sheet 
Selection:  - or E 
 
Function 
No. 
Function Name 
1 Disarm 
Use the disarming function to disarm areas that are 
master armed or perimeter armed. If enabled, the 
following disarming choices are available to the user 
with this authority: 
  DISARM ALL: Disarms all areas within the CC# 
Scope of the keypad being used by accessing 
the Function Menu and the authority level of the 
user performing the function. 
  DISARM AREA: Disarms only the displayed 
area. 
 
Many options are available for arming 
and disarming. Selecting an option 
depends on A# Area Type and CC# 
Scope
. Read the definitions of area type 
in Section 2.8 Area Parameters on page 
5 and CC# Scope in Section 2.9.1 
Keypad (Command Center) Assignment
 
on page 50.