D9412GV3/D7412GV3 | Program Entry Guide | 2.0  Panel and Area Wide Parameters 
EN | 74 
 
 
Bosch Security Systems, Inc. | 10/11 | F01U170807-02 
 
  Events print locally without alarm annunciation or 
reporting to the central station receiver. 
  D1255 Keypad displays a sequential count and 
the text for the point after each point is activated 
and restored.  
  The D1255 Keypad displays ALL PNTS 
TESTED. 
  If enabled in Routing, Service Start and Service 
End are reported at the central station receiver 
for the beginning and end of the test. 
Point 128 and Point 248 appear as missing. This is 
normal. These points are used for supervising the 
Zonex 1 bus (Point 128) and Zonex 2 bus (Point 
248). If the Zonex bus has a fault, these points 
indicate a short.  
This function allows viewing of extra points. Extra 
points occur under two conditions: an extra point is 
wired electrically to the Zonex bus with P### Point 
Index
 set to 0, or two Zonex devices exist for the 
same Zonex address. 
L## Default Text 
Default: 
Refer to the program record sheet 
Selection:  - or E 
 
Function 
No. 
Function Name 
Alternate 
Keystroke 
34 Default 
Text 
[COMMAND][5][7] 
Temporarily show the armed state of the area using 
control panel default text, A# AREA # IS ON, A# NOT 
READY, A# AREA # IS OFF, and A# ACCOUNT IS 
ON. 
L## Change Skeds 
Default: 
Refer to the program record sheet 
Selection:  - or E 
 
Function 
No. 
Function Name 
Alternate 
Keystroke 
35 Change 
Skeds 
[COMMAND][5][2] 
Change skeds that can be edited. 
 
Editing of skeds can be restricted by 
programming S## Time Edit? to No
 
L## Invisible Walk Test 
Default: 
Refer to the program record sheet 
Selection:  -, or E 
 
Function 
No. 
Function Name 
Alternate 
Keystroke 
36 
Invisible Walk Test 
(Menu function only) 
Test all points that are programmed to be invisible 
and that are within the scope of the keypad without 
sending reports to the central station. Invisible points 
must be programmed P## Invisible Point as Yes
This walk test mode can test 24-hour points and 
controlled points. 
Invisible Test? allows the user with this L## to start 
an invisible walk test for all 24-hour interior and 
posterior controlled points in the area to which this 
keypad is assigned. When an invisible test is started, 
one person can test invisible points without 
assistance.  
The following features are provided with the Invisible 
Test Mode: 
  The display indicates exactly how many invisible 
points are assigned to the area. 
  Battery and bell tests do not occur during this 
walk test. 
  The keypad shows point text when invisible 
points are tested. 
  The test ends when all points are tested, or if the 
test times out after 10 min of no activity. 
  Local event printing occurs without alarm 
annunciation or reports sent to the central station 
receiver. 
  The D1255 Keypad shows a sequential count 
and text related to the point after each point is 
activated and restored. 
  The keypad shows All PTS TESTED. An All 
Points Tested Event is sent to the central station 
receiver (if programmed) when the last point is 
tested. 
  Walk Start and Walk End Reports are sent to the 
central station receiver for the beginning and end 
of the test (if programmed in phone routing).