Bosch Appliances Video Game Controller d9412gv3 User Manual

Page of 154
D9412GV3/D7412GV3 | Program Entry Guide | 2.0  Panel and Area Wide Parameters 
EN | 86 
 
 
Bosch Security Systems, Inc. | 10/11 | F01U170807-02 
 
U### Name 
Default: 
Refer to the program record sheet 
Selection: 
Sixteen alphanumeric characters 
Enter Alphabetic-characters A to Z in capital letters 
Period (.), comma (,), percent (%), parentheses [()], 
equal (=), greater or less than (< >), exclamation (!), 
braces ({}), apostrophe (’), carat (^), grave accent (`), 
tilde (~), semi-colon (;), and colon (:) are not allowed. 
Enter up to sixteen characters of text for this user 
group. 
 
Programming this group with a 
departmental, team, or function name 
identifies all the users in this group in a 
function related manner, such as 
ENGINEERING. 
Card Data Format 
The D9412GV3/D7412GV3 and D9210B Controller 
comply with the 26-bit Wiegand card data format. In 
essence, the format consists of 26 bits (3.2 bytes) of 
data. The first bit is used for the even parity. The next 
8 bits (first byte) is used for the U### Site Code. The 
next 16 bits (second and third byte) are used for the 
U### Card Data. The last bit is used for the odd 
parity. 
As long as the reader and the tokens or cards you 
use are compatible with 26-bit Wiegand format, they 
function with this system. 
Use only the readers identified as being compatible 
with the D9210B door control module. Refer to the 
D9210B Operation and Installation Guide 
(P/N: 32206) for information on these readers. 
For more information, refer to the Security Industry 
Association (SIA) Access Control 26-bit Wiegand 
Reader Interface Standard
U### Mstr Site 
Default: 
255 
Selection: 
0 to 255 
Master User ### Site Data: Enter the first three 
decimal numbers on the back of the token or card. 
This is the first byte (bits 2 through 9) of data for a 
26-bit Wiegand card. This is called the site number. 
Tokens and cards with a site code of 255 are not 
compatible with the D9412GV3/D7412GV3 Control 
Panels. 
 
 
Converting hexadecimal to decimal: If 
your card label contains letters as well as 
numbers, the number is hexadecimal.* 
Convert the hexadecimal number to 
decimal using your calculator. If you 
cannot convert in this way, use the reader 
and the Add/Chg User? Function to add 
the tokens or cards. 
Perform the following test to confirm that 
you can convert properly: 
Use 319EB0 as the hexadecimal number. 
On your calculator, press [HEX]. Enter all 
the hexadecimal characters into the 
calculator. Press [DEC] and your 
hexadecimal characters convert to the 
following eight digits: 03251888. The site 
number is 032.  Enter it in U### Mstr 
Site
. Your card data is 51888. Enter it into 
U### Mstr Crd Data
*   A hexadecimal number can contain all numerals. If the 
code does not work, try converting the number from 
hexadecimal to decimal. 
 
Always tag your tokens before adding 
them to the system so you do not mix 
them up. Use the CRD ID ###-# number 
to index them. 
U### Mstr Crd Data 
Default: 
Blank 
Selection:  00000 = (0) to 65534 or Blank 
(65535) 
Master User ### Card Data: Enter the remaining 
five decimal numbers on the back of the token or 
card. This is the second and third byte (bits 10 
through 25) of data for a 26-bit Wiegand card. This is 
called the card data. 
You must program U### Mstr Site before 
programming this prompt. 
U### SU1 through SU3 Site 
Default: 
255 
Selection:  0 to 255 
Sub-users one through three site data. 
U### SU1 through SU3 C/D 
Default: 
Blank 
Selection: 
00000 = (0) to 65534 or Blank 
(65535) 
Card data for sub-users one through three.