Bosch Appliances Computer Hardware DVA-08K User Manual

Page of 68
30
en | Subsystem Monitoring
RAID Subsystem DVA-08K | Installation Manual
F.01U.027.797 | V2 | 2008.08
Bosch Security Systems
4.2.5
BBU Module LED
The BBU module has an LED on its faceplate. (See Figure 4.4The function is the same as the 
fifth LED on the controller module. The LED is off when the BBU is functioning normally and is 
able to sustain the cache memory. The LED flashes to indicate the BBU is currently charging 
its battery cells. If the LED is illuminating amber, the unit may have failed. Please contact your 
system vendor to verify the problem. 
Fig. 4.4
BBU Module LED
4.2.6
PSU LED
Fig. 4.5
PSU LED
Each PSU comes with a single LED located just above the power switch and just below the 
retention screw (see Figure 4.5). The LED is used to indicate the operational status of the PSU 
module. Please refer to the PSU LED definitions shown in Table 4.5.
4.2.7
LCD Keypad Panel
The LCD panel located on the front aluminum foldable handle comes with three status LEDs. 
The LEDs are marked from top to bottom “PWR,” “BUSY” and “ATTEN” and are clearly seen in 
Figure 4.6 below. The definitions of these LEDs are shown in Table 4.6. The mute button can 
be used to stop the alarm until the next controller event occurs.
Fig. 4.6
LCD Keypad Panel
Color
Status
Flashing Green
The power supply has not been turned on. The PSU module LED will 
blink when the subsystem is connected to a power source but has not 
been turned on.
Static Green
The PSU is operating normally and experiencing no problems
Static Red
The PSU has failed and is unable to continue providing power to the 
subsystem.
OFF
The power cord is unplugged or the power cord is plugged but no 
power is being supplied from the power source. 
Table 4.5
PSU Module LED Definitions