4424 Blade Server SAN I/O Module Hardware Reference Manual
53-0000571-01
Cabling guidelines
1
5. Be sure that you have taken the necessary precautions for electrostatic sensitivity; then break 
the seal warning.
6. Slide the SAN I/O Module out of the antistatic sleeve and inspect it carefully for any obvious 
defects or shipping damage. 
7. Locate the label that specifies the part number for the SAN I/O Module. Make a note of the 
part number because the part number indicates whether the SAN I/O Module was configured 
at the factory in Access Gateway or Standard Full Fabric Switch mode. (More information on 
Access Gateway and Full-Fabric Switch mode is provided in 
.)
If the part number is DL-4424-0003, then the SAN I/O Module is configured in Access 
Gateway mode.
If the part number is DL-4424-0001, then the SAN I/O Module is configured in Full Fabric 
Switch mode. Note that Full Fabric Switch mode is the default factory setting when the 
module is licensed for Dual Function mode. With Dual Function mode, you can enable the 
module for Access Gateway or Full Fabric Switch mode.
8. For complete instructions to install the SAN I/O Module into the Blade Server Enclosure, refer 
to the section on installing an I/O module in the Blade Server Enclosure Hardware Owner’s 
Manual
.
Cabling guidelines
After modifying the SAN I/O Module’s IP address and domain name (if Module is in Fabric Switch 
mode), we recommend that you cable all external ports to fabric connections before bringing the 
SAN I/O Module online. Refer to 
 for steps on 
modifying the IP address.
Begin by cabling ports 17, 18, 19, 20, 21, 22, 23, and 0. Ports 17 and 18 are licensed at the 
factory as part of Dynamic Ports On Demand (DPOD). By cabling these ports first, you will not need 
to move licenses to other ports you may have cabled.