Brocade Communications Systems 53-1000571-01 User Manual

Page of 48
4424 Blade Server SAN I/O Module Hardware Reference Manual
21
53-0000571-01
Interpreting POST results
3
Secure Telnet access is available using Secure Shell (SSH), a network security protocol for secure 
remote login and other secure network services over an insecure network.
Brocade Web Tools management is available through a secure browser using Secure Sockets Layer 
(SSL). The SSL security protocol provides data encryption, server authentication, message integrity, 
and optional client authentication for a TCP/IP connection. Because SSL is built into all major 
browsers and Web servers, installing a digital certificate enables the SSL capabilities.
Interpreting POST results
The power-on self test (POST) system check is performed each time the SAN I/O Module is powered 
on, rebooted, or reset. 
Example POST Output
POST1: Started running Tue Nov  9 20:27:57 GMT 2004
POST1: Test #1 - Running turboramtest
POST1: Test #2 - Running centralmemorytest
POST1: Test #3 - Running cmitest
POST2: Running diagshow
POST1: Script PASSED with exit status of 0 Tue Nov  9 20:28:10 GMT 2004 took 
(0:
0:13)
POST2: Started running Tue Nov  9 20:28:12 GMT 2004
POST2: Test #1 - Running camtest
POST2: Test #2 - Running txdpath
POST2: Test #3 - Running spinsilk (SERDES)
POST2: Running diagshow
POST2: Script PASSED with exit status of 0 Tue Nov  9 20:29:11 GMT 2006 took 
(0:
0:59)
Initializing Ports ....
Port Initialization Completed
Enabling switch...
During POST, the LEDs are activated in various indicator patterns.
Perform the following steps to determine POST completion status.
1. Verify that the LEDs on the SAN I/O Module indicate a healthy SAN I/O Module. LED patterns 
are described in 
 next.
If one or more LEDs do not display a healthy state, verify that the LEDs are not set to beacon. 
Use the SAN I/O Module CLI switchShow command or Web Tools to verify the LED state. For 
information about how to turn beaconing on and off, see the Fabric OS Administrator’s Guide 
or the Web Tools Administrator’s Guide.
2. Use the Blade Server Enclosure’s Chassis Management Controller (CMC) GUI to verify that the 
SAN I/O Module is working correctly. 
For details, refer to the Hardware Owner’s Manual for the Blade Server Enclosure.
3. Review the system log for errors.
Any errors detected during POST are written to the system log. Access this log through the 
Module’s CLI errShow command. For information about this command, see the Fabric OS 
Command Reference Manual
. For information about error messages, see the Fabric OS 
System Error Message Reference Manual
.