Bosch Appliances Security Camera FW5 User Manual

Page of 100
Camera Browser Interface
Setting up VCA | en
75
Bosch Security Systems
Software manual
AM18-Q0605 | v5.0 | 2011.07
13.2
VCA - Profiles
Two profiles can be set up with different VCA configurations. 
You can save profiles on your computer's hard drive and load 
saved profiles from there. This can be useful if testing a number 
of different configurations. Save a functioning configuration and 
test new settings. Use the saved configuration to restore the 
original settings at any time.
1.
In the VCA configuration drop-down list, select profile 1 or 
2 and enter the required settings.
2.
If necessary, click Default to return all settings to default 
values.
3.
Click the Save... to save the profile settings to another file. 
A new window opens where you specify the file name and 
the location.
4.
Click Load... to load a saved profile. A new window opens 
where you select the location and the profile file.
To rename a profile:
1.
To rename the file, click the icon to the right of the list field 
and enter the new profile name in the field.
2.
Click the icon again. The new profile name is saved.
The current alarm status is displayed for information purposes.
13.2.1
Aggregation time [s]
Set an aggregation time of between 0 and 20 seconds. The 
aggregation time always starts when an alarm event occurs. It 
extends the alarm event by the value set. This prevents alarm 
events that occur in quick succession from triggering several 
alarms and successive events in a rapid sequence. No further 
alarm is triggered during the aggregation time.
The post-alarm time set for alarm recordings only starts once 
the aggregation time has expired.