4-Wire Cable from Home Power Supply
IMPORTANT: Use the 4-wire cable from home power supply in 
the U.S. where local codes do not allow grounding through 
neutral, New Branch circuit installations (1996 NEC), mobile 
homes and recreational vehicles, new construction and in 
Canada.
1. Connect the 2 black wires (B) together using a UL listed wire 
connector.
2. Connect the 2 red wires (C) together using a UL listed wire 
connector.
3. Untwist white wire from green (or bare) ground wire coming 
from the  oven.
4. Connect the 2 white wires (F) together using a UL listed wire 
connector. 
5. Connect the green (or bare) ground wire (H) from the oven 
cable to the green (or bare) ground wire (in the junction box) 
using a UL listed wire connector.
6. Install junction box cover.
3-Wire Cable from Home Power Supply - U.S. Only
IMPORTANT: Use the 3-wire cable from home power supply 
where local codes permit a 3-wire connection.
1. Connect the 2 black wires (C) together using a UL listed wire 
connector.
2. Connect the 2 white wires (D) and the green (or bare) ground 
wire (of the oven cable) using a UL listed wire connector.
3. Connect the 2 red wires (G) together using a UL listed wire 
connector.
4. Install junction box cover.
A. Cable from home power supply
B. Black wires
C. Red wires
D. 4-wire flexible cable from oven
E. Junction box
F. White wires
G. UL listed wire connectors
H. Green (or bare) ground wires
I. UL listed or CSA approved 
conduit connector
A
B
C
D
E
F
G
H
I
A. Cable from home power supply
B. Junction box
C. Black wires
D. White wires
E. Green (or bare) ground wire 
(from oven)
F. 4-wire flexible cable from oven
G. Red wires
H. UL listed wire connectors
I. UL listed or CSA approved 
conduit connector
B
C
D
E
F
H
G
A
I