TROUBLESHOOTING
© 2003 Wagan Corporation.
Condition
Solution
Poor contact
Clean contact parts thoroughly
Battery voltage is 
too low 
Start the engine to recharge the 
battery. Replace the battery if 
needed.
Shutdown on 
overload
Reduce the wattage of inverter’s load 
Thermal shutdown
Allow the inverter to cool down by 
reducing the load or turn it off for a 
while.
Receptacle has no 
power
Check the receptacle wiring.
HINTS
Adding Extension Cord 
If you need extension cord, we recommend the use of an 
extension cord between the AC output of inverter and 
AC appliances.  You may use up to 100 ft. of high quality 
extension cord.  A long cord will result in reduced output
power.
Buzz in audio system
Some stereo systems and “boom boxes” will emit a 
buzzing noise from their loudspeakers when operated
from the power inverter because the power supply in the 
device does not adequately filter the modified sine wave
produced by the power inverter. The only solution is to
use a sound system that incorporates a higher quality
power supply.
Operating a TV
Picture tubes have a degaussing coil that uses a high 
initial surge of power to light up the screen from a “cold
start”.  If the TV does not start up on the first try, switch 
ON the TV every 2 - 3 seconds until the screen comes
on.  Sometimes, it may take 2-5 tries before starting.
Television interference
Operating of the power inverter can interfere with
television reception on some channels. If this situation
occurs, the following steps may help to alleviate the 
problem.
1.
Make sure that the chassis ground lug on the back 
of the power inverter is solidly connected to the 
ground system of your vehicles.
2.
Do not operate high power loads with the power
inverter while watching television.
3.
Make sure that the antenna feeding your television 
provides an adequate (“snow free”) signal and that 
you are using good quality cable between the 
antenna and the television.
4.
Move the television as far away from the power 
inverter as possible.
5.
Keep the cables between the battery and the power 
inverter as short as possible and twist them together
with about 2 to 3 twists per foot. This minimizes
radiated interference from the cables.
MAINTENANCE
Very little maintenance is required to keep the inverter
operating properly.
DESCRIPTION
3500W Peak Power — allow you to power appliances 
that require a large amount of initial (peak) power to 
work (such as many TVs and motor-power equipments).
Low Battery Alarm — the inverter sounds an audible
alarm then turns itself off if the source battery becomes
too low. 
Auto Shutdown/Reset Protection — the inverter
temporarily shuts itself down to protect itself from 
overheating.
Overload/Short Circuit Protection — the inverter
automatically turns itself off if the connected load is too
high or if it shorts.
Fuse — the inverter comes with fuse/s already installed
and can be changed if it is damaged.
Dual AC Outlets — allows you to power up to two 
appliances at the same time.
www.wagan.com
All Rights Reserved. 
Wagan and Wagan.com are trademarks used by Wagan Corporation.
Printed in China
4