Sylvania 66136 User Manual

Page of 4
OPERATING INSTRUCTIONS
OSRAM
8/12/00
SYLVANIA
     
Process Heat
131 Portsmouth Ave.  Exeter, NH 03833  USA     Tel: 800-258-8290      Fax: 603-772-1072
1
G-TEMP HEATER
065253, 066136, 070282
  FOR SAFETY AND LONG HEATER LIFE, CAREFULLY READ THIS MANUAL BEFORE USE.
Description
Compact, efficient heater with integrated temperature and power controller for heating air or inert gases to
1300°F (700°C).   A thermal sensor in the control box turns the heater power off if airflow is lost, or the inlet air
temperature is too high.  A built-in airflow damper controls airflow, and control potentiometer controls
temperature.   If operated correctly, the heater will operate continuously for 5000 hours or longer.
Specifications
MAXIMUM INLET PRESSURE 
2 PSI (.14 BAR)
MAXIMUM INLET AIR TEMPERATURE 
100°F (38°C)
MAXIMUM EXIT AIR TEMPERATURE 
1300°F (760°C)
MODEL
NUMBER
MAXIMUM
WATTAGE
SUPPLY
VOLTAGE
AMP
RATING
REPLACEMENT
ELEMENT
NUMBER
066136
1500
120   - 60 Hz
13
066137
065253
3000
230   - 60 Hz
15
065335
070282
3000
230   - 50 Hz
15
065335
Safety
SHOCK HAZARD  Only qualified individuals should install this heater and related controls. Follow all applicable
electrical codes and use proper wiring.