Spectra Watermakers VENTURA 150 MPC-5000 User Manual

Page of 54
If you do not have adequate space to install the feed pump inlet module it is possible to re-
move and relocate the feed pump. Before you install the module, disconnect the hose that 
connects the feed pump to the module plumbing. Remove the cooling fan  and the heat sink 
from the pump. Both are friction fits with no fasteners. Remove the 4 machine screws hold-
ing the pump to the module. 
Feed Pump Relocation 
Cooling fan  
Heat sink 
With the pump on a flat surface. Remove the three 
screws that hold the pump head on.     See Fig1 
 
Re-orient the pump head 120 degrees. See Fig2 
 
Reinstall the screws and tighten firmly. See Fig3 
 
Now the feed pump may be installed where you wish. 
Do not install with the pump head over the motor in-
case of leaks.  Wire size may have to be increased if 
wire runs are longer. 
Fig 1 
Fig 2 
Fig 3 
Machine Screws