Spectra Watermakers Newport 400 User Manual

Page of 58
 
Component Placement 
             Refer to the Plumbing Diagrams 
Strainer 
 
Mount the strainer in an accessible area close to the intake through-
hull that can handle water spillage during service. Extra care during 
assembly must be taken to avoid air leaks from the strainer. Use the 
supplied “Quick Block” and wire tie for mounting. 
The fresh water flush module may be located in any convenient location 
near the Feed pump module. It should be mounted with the filter hous-
ing vertical and  accessible for changing filters. Allow 2” below the fil-
ter housing for removal. Do not install over electrical equipment. The 
unit contains a charcoal filter for the flush water, flush solenoid and  
flush water pressure regulator. 
 
Feed Pump Module 
 
Fresh Water Flush Module 
Mount the feed pump module on a horizontal or vertical sur-
face that can be up to 3’ (1.0M) above the waterline. It is 
preferable to mount as low as possible. Locate in an area that 
allows easy access to  the filters and left hand side and where 
water spills during filter changes will not be a problem. Keep 
future maintenance in mind when choosing a location.  The 
feed pump has overheat protection and will not operate prop-
erly at ambient temperatures over 120F (48C).  
 
Remove  front cover 
to access mounting 
holes in the enclo-
sure.  
Boost Pump module
 
The boost pump module should be 
mounted vertically with the service hose 
connection at the top.  The boost pump 
must be installed below the water line to 
ensure that it will prime.