Source Technologies SECURE MICR PRINTER ST9630 User Manual

Page of 79
 
Source Technologies, LLC                                                             ST9630 Secure MICR Printer User’s Guide 
 
71 
Fonts and Secured Resources 
The ST Secure MICR printer has five fonts password protected in Flash memory. The 
printer requires PJL commands with the correct password value to unlock the font 
resources, followed by PCL to print the fonts. They are then re-locked by PJL commands 
or by a printer power cycle. 
 
The PJL commands to unlock the fonts must precede all PCL commands. The re-lock 
PJL commands must follow the PCL commands and final form feed command. The PCL 
commands could print an unlimited number of pages between the unlock and re-lock 
sequences. The following examples will use <ESC> to indicate the Escape character, 
ASCII 27. Values shown in parentheses () are hexadecimal. 
 
PJL Unlock Sequence 
<ESC>%-12345X@PJL LDECLARE LRESOURCE:”flash:” 
LRWLOCK=”PASSWORD”(0D)(0A) @PJL ENTER LANGUAGE=PCL(0A) 
 
The sequence contains a UEL (Universal Exit Language) command followed by the 
unlock and enter language commands. The commands are case sensitive. PASSWORD 
is the initial default password value. The command delimiter is a Line Feed (hex 0A) with 
Carriage Return (hex 0D) being optional. Spaces are required as shown. The ENTER 
LANGUAGE command is optional but recommended. The command should also end 
with a LF (hex 0A). At this time all secured resources including any resources that are 
customer unique in Flash are unlocked and available to PCL. 
 
The password value is limited to no more than 8 alphanumeric, case-sensitive 
characters. 
 
PJL Re-Lock Sequence 
<ESC>%-12345X@PJL LDELETEPASSWORD LRESOURCE:”flash:”(0D)(0A) 
<ESC>%-12345X 
This sequence re-locks the resources with no change in the password value. The PJL 
syntax of LDELETEPASSWORD is not the password. The command sequence 
terminates with the UEL command (Universal Exit Language). This is optional but 
recommended. 
 
PJL Re-Lock Sequence With A New Password Value 
<ESC>%-12345X@PJL DEFAULT LRESOURCE:”flash:” 
LRWLOCK=”xxxxxxxx”(0D)(0A) 
<ESC>%-12345X 
 
This command requires the resources to be previously unlocked. The new password is 
represented by the value xxxxxxxx. The UEL is again optional but recommended. 
After consulting Lexmark Technical Reference materials you may wish to expand the 
PJL sequences to include more than the examples above. To chain multiple PJL 
commands follow the following format: 
(UEL)(PJL COMMAND)(0A)(PJL COMMAND)(0A)(PJL COMMAND)(0A)(UEL or ENTER 
LANGUAGE) 
 
The normal printer action to any format problems or missing or extra symbols is to ignore 
the PJL command. 
 
Appendix G