Setup Relating to Switcher Processor
  
Ch
apt
er 16 
E
ngin
eering Se
tup
2
Press [V Blank Mask].
3
Adjust the parameter.
a) Depending on the signal format, the adjustment range varies as follows.
• 480i: 10 to 19
 576i: 6 to 22
To return the values to their defaults, press [Default].
4
To enable the through mode, press [Through Mode], setting it to Enable.
The through mode can be applied to the following outputs.
• Aux 1 to 48
• Program outputs of the M/E and PGM/PST rows
• Clean outputs of the M/E and PGM/PST rows
Making safe title settings
Use the following procedure.
1
In the Switcher>Output menu, press [Safe Title].
The Safe Title menu appears.
The status area shows the output ports and the assigned signals, with the 
box 1, box 2, and cross states.
2
To enable the safe title on/off setting made in the Misc menu, press [Safe 
Title], turning it on.
3
Carry out either of the following operations.
To display a box: Press [Box1] or [Box2], turning it on.
In this case, carry out the following steps 
4
 and 
5
.
To display a cross: Press [Cross], turning it on.
4
When you selected [Box1] or [Box2] in step 
3
, adjust the following 
parameters.
Knob
Parameter
Adjustment
Setting values
2
Mask End
Final value for vertical blanking 
interval
See note a) below
Knob
Parameter
Adjustment
Setting values
2
Box Size
Box size
50.00 to 100.00
3
Luminance
Display brightness
0.00 to 100.00
 a)