USAGE LICENSES 
RCF  radiomicrophone  systems  fully  comply  with  all  the  regulations 
currently in force. In certain countries, however, the use of radiofrequency 
systems must be approved by the local authorities and it may be necessary 
to request a licence for legal use. Your local dealer or the distributor can 
provide you all the necessary information.
TECHNICAL DATA
COMMON DATA
CARRIER FREQUENCY 
 VHF range, 174÷240 MHz
MODULATION 
 FM
NOMINAL DEVIATION 
 50 kHz min. @ 1 kHz sinusoidal  
FREQUENCY STABILITY 
 10 kHz max. (-10°C ÷ +50°C)
FREQUENCY RESPONSE 
 40 Hz ÷ 15 kHz
DISTORTION (THD) 
 < 1% at nominal deviation
SIGNAL / NOISE RATIO 
 > 100 dB (A)
RECEIVERS RX 1000 / RX 1001-AFP
DIMENSIONS
 35 x 110 x 220 mm
POWER SUPPLY 
 12 V – AC (adapter provided; 
                                                                                 see its data label)
CONSUMPTION (current) 
 250 mA
AUDIO OUTPUT 
 max. 0 dBv, balanced
DYNAMIC EXPANDER 
 quadratic
WEIGHT 
 < 0.5 kg
TRANSMITTERS TX 1000 / PX 1000
POWER SUPPLY 
 9 V (9 V alkaline battery – IEC 6LR61)
CONSUMPTION (current) 
 < 40 mA
IRRADIATED POWER 
 +10 dBm ERP
COMPANDER 
 quadratic
ANTENNA 
 built-in
AUDIO INPUT (PX 1000)
 3.5 mm jack, screw locking
AUDIO INPUT SENSITIVITY (PX 1000)
 50 mV - 5 V RMS
LOW BATTERY CHARGE INDICATION 
 yes
INDICATIVE BATTERY LIFE 
 8 ÷10 hours
WEIGHT (approx.) 
 220 g