Raypak MVB TYPE B 504-2004 Leaflet

Page of 2
Catalog No.:  6000.29B 
Effective:  7-15-08 
Replaces:  1-1-08
 
Job: 
 
           
 
Engineer: 
 
           
 
Contractor: 
 
           
 
Prepared By: 
            
 Date:
             
 
Model:  
         
 
 Indoor/Outdoor:  
         
 
 
85% Thermal Efficiency 
100% Factory Fire Tested  
Minimum Acceptable Inlet Water Temperature: 105°F 
Full Safety Diagnostics with History 
Footprint: Less Than 5-1/2 ft
2
 
Limited Twenty-Year Thermal Shock Warranty 
Limited Five-Year Heat Exchanger Warranty 
On/Off Firing 
Soft-Start Modulating Controller with LCD Display 
Status Display Lights 
 
 
Heat Exchanger 
  Bronze Headers   
  ASME HLW Stamped 
160 PSIG Working Pressure 
  National Board Approved 
  Cupro Nickel Fin Tubing 
  ASME Powder-Coated Tube Sheet 
  Silicone High Temp O-Rings 
  ASME Pressure Relief Valve, 
125 PSIG  
  Temperature and Pressure Gauge, 
Shipped Loose 
  Stainless Steel Evaporator Plate 
  Bronze Pump (See table on pg. 2) 
  Drain Valves (2) 
  Air Vent 
Control 
  120V, 60Hz, 1Ø, Power Supply 
  120/24V 60Hz Transformer 
  Ignition Module 
 3-Try – Standard 
 Single-Try – Option C-6 
  Hot Surface Ignition (HSI) 
  Remote Flame Sensor 
  High Limit, Auto Reset, Adj., 140°F 
  High Limit, Manual Reset, Fixed 
Models 504-1504:  175°F 
Models 2004:  200ºF 
  On/Off Power Switch 
  Flow Switch, Mtd 
  Blocked Vent Pressure Switch 
  Combustion Air Proving Switch 
  Pump Switch 
  Pump Time Delay 
  Diagnostics Panel 
Control (cont.) 
  On/Off Digital Poolstat, 106°F Max 
  Water Temperature Sensors (3) with 
Immersion Well 
Burner 
  Ultra-Low NOx: Less than 20 PPM 
Gas Train  
  Fuel 
 Natural Gas 
 Propane 
  Zero Governor Regulator 
  Dual-Seat Combination Valve 
  On/Off Firing with Soft-Start 
Construction 
  Indoor/Outdoor Construction 
  Enclosed Front Controls 
  PolyTuf Powder Coat Finish 
  Rear Connections (Water, Electrical, 
Gas, Vent, Combustion Air) 
  Design Certification 
Models 504-1504:  ANSI Z21.56/ 
CSA 4.7 
Model 2004:  ANSI Z21.10.3/CSA 4.3 
Venting 
  Vent Termination Cap 
 Outdoor – Option D-11 
 Indoor, Horizontal – Option D-15 
 Indoor, Vertical (by others) 
  Combustion Air 
 In-Line Filter Kit – Option D-17 
 Air Intake Elbow – Option D-16 
  Extractor – Optional 
 By others 
 Not required 
Temperature Controllers 
 B-26  TempTracker Digital Controller,  
Up to 2 Heaters 
 B-21   TempTracker Digital Controller,  
Up to 4 Heaters 
 Y-241  Electronic Sequencer,  
Up to 4 Heaters 
 Y-281  Electronic Sequencer,  
Up to 8 Heaters 
Options 
 F-10  Low Water Cut-Off, Remote 
Probe 
 P-      Cold Water Run 
 P-      H-style Bypass, Non-Ferrous 
 S-1 
Low Gas Pressure Switch,  
Manual Reset 
 S-2 
High Gas Pressure Switch, 
Manual Reset 
Regulatory Agency Requirements 
            
 
 
MVB
®
 
- Type P 
    Pool Heaters 
Models 504-2004 
Pump included 
standard 
L
W