Faber 1200 CFM User Manual

Page of 8
Version 05/06 - Page 1
Observe all governing codes and ordinances.  Proper installation 
is  your  responsibility.    Make  sure  you  have  everything  necessary  for 
correct installation. It is the responsibility of the installer to comply with 
the clearances specified. 
To avoid damage to motor bearings and impellers, keep drywall spray, 
construction dust, etc. away from the remote blower.
Before  installing  remote  blower,  read  the  installation 
instructions  for  the  vent  system  that  will  be  used  in 
conjunction with this remote blower.
Important
READ  AND  SAVE  THESE  INSTRUCTIONS
The  installer  must  leave  these  instructions  with  the 
homeowner.    The  homeowner  must  keep  these 
instructions for future reference and for local electrical 
inspectors' use.
Care of your remote blower
Disconnect power supply and lock out service panel before cleaning 
or
servicing.    To  clean,  remove  cover  and  vacuum  blower  and  housing, 
being careful not to damage blower wheel.  The motor is permanently 
lubricated.  Do not oil or disassemble.
Electrical requirements
Important: Observe all governing codes and ordinances.
It is the customer’s responsibility:
• To contact a qualified electrical installer.
• To assure that the electrical installation is adequate and in 
conformance with:
National Electrical Code, ANSI/NFPA 70 — latest edition*, or CSA 
Standards C22.1-94, Canadian Electrical Code, Part 1 and C22.2 
No.0-M91 - latest edition** and all local codes and ordinances.
If codes permit and a separate ground wire is used, it is recommended 
that a qualified electrician determine that the ground path is adequate.  
Do not ground to a gas pipe.  Check with a qualified electrician if you 
are not sure remote blower is properly grounded.  Do not have a fuse in 
the neutral or ground circuit.
A  120-volt,  60-Hz,  AC-only  supply  wired  for  15  amp  service  is 
required.
The blower motor must be connected with copper wire only.
The remote blower must be connected to the downdraft vent system 
or  rangehood  wiring  as  described  in  the  downdraft  vent  system  or 
rangehood instructions for connecting the remote blower motor wiring. 
Flexible armored or nonmetallic cable must be used. A U.L./CSA-listed 
strain relief must be provided at each end of the power supply cable.  
Wire sizes must conform to the requirements of the National Electrical 
Code ANSI/NFPA 70 — latest edition* or Canadian Electrical Code, C22.1 
and C22.2 No. 113-M1984 (or latest edition),** and all local codes and 
ordinances. 14 gauge wire (minimum) is recommended.
Remote Blower (1200 CFM) 
Installation Instructions
Use & Care Manual
You can be killed or seriously injured if you don’t 
follow instructions.
TO  REDUCE  THE  RISK  OF  FIRE,  ELECTRIC 
SHOCK, OR INJURY TO PERSONS, OBSERVE THE 
FOLLOWING:
Installation  work  and  electrical  wiring  must  be 
done by qualified person(s) in accordance with all 
applicable  Codes  and  Standards,  including  Fire 
Rated  Construction.    Sufficient  air  is  needed  for 
proper combustion and exhausting of gases through 
the  flue  (chimney)  of  fuel  burning  equipment  to 
prevent back drafting.  Follow the heating equipment 
manufacturer’s guideline and safety standards such 
as those published by the National Fire Protection 
Association  (NFPA),  and  the  American  Society  of 
Heating Refrigeration and Air Conditioning Engineers 
(ASHRAE),  and  the  local  code  authorities.  When 
cutting or drilling into wall or ceiling, do not damage 
electrical wiring and other hidden utilities. Ducted 
fans must always be vented to the outdoors.
Use  this  unit  only  in  the  manner  intended  by  the 
manufacturer.  If you have any questions, contact 
the manufacturer.
Before servicing or cleaning unit, switch power off 
at service panel and lock the service disconnecting 
means to prevent power from being switched on ac-
cidentally.  When the service disconnecting means 
cannot be locked, securely fasten a prominent warning 
device, such as a tag, to the service panel.
WARNING - TO REDUCE THE RISK OF SHOCK: This 
fan must be installed with an isolating wall control/
switch.
CAUTION: For General Ventilating Use Only.  Do Not 
Use To Exhaust Hazardous  or  Explosive Materials 
and Vapors.
To reduce the risk of fire, use only metal ductwork.
This unit must be grounded.
This unit is suitable for use with solid-state speed 
controls.
For Residential use ONLY
Copies of standards listed may be obtained from:
* National Fire Protection Association
One Batterymarch Park
Quincy, Massachusetts 02269
** CSA International
8501 East Pleasant Valley Road
Cleveland, Ohio 44131-5575
   WARNING
!
CAUTION – To reduce risk of fire and to properly 
exhaust air, be sure to duct air outside – Do not vent 
exhaust air into spaces within walls or ceilings or 
into attics, crawl spaces, or garages”