Charmglow 720-0289 User Manual

Page of 31
 
12
Only the pressure regulator and hose assembly supplied 
with the grill should be used. Any replacement pressure, 
regulator and hose assembly must be specified by the grill 
manufacturer. 
This is a liquid propane configured grill.   
Do not attempt to use a natural gas supply unless the grill 
has been pre-configured for natural gas use. 
 
Total gas consumption (per hour) of 720-0289 grill with all 
burners on “HI”: 
 
Main burners   
40,000 Btu/hr. 
Sear burner        18,000 Btu/hr 
Side burner        12,000 Btu/hr. 
Rotisserie burner 
15,000 Btu/hr. 
Total  
 
     85,000 Btu/hr. 
 
The installation of this appliance must conform with local 
codes or, in the absence of local codes, with the national 
fuel gas code, ANSI Z223.1 Installation in Canada must be 
in accordance with the Standard CAN/CG A-B149.2 
(installation code for gas burning appliances and 
equipment) and local codes. 
 
LP Gas Cylinder Requirements (20lb.Cylinder) 
A dented or rusty LP Gas Cylinder may be hazardous and 
should be checked by your LP supplier. Never use a 
cylinder with a damaged valve. The LP gas cylinder must be 
constructed and marked in accordance with the 
specifications for LP gas cylinders of the U.S. Department 
of Transportation (DOT), or the National Standard of 
Canada, CAN/CSA-B339, Cylinders, Spheres and Tubes for 
Transportation of Dangerous Goods; and Commission. 
 
The 20lb. cylinder must be provided with a shut off valve 
terminating in an LP gas supply cylinder valve outlet 
specified, as applicable, for connection type QCC1 is the 
standard for compressed gas cylinder valve outlet and inlet 
connection ANSI/CGA-V-1. 
 
The cylinder supply system must be arranged for vapor 
withdrawal. The cylinder must include a collar to protect the 
cylinder valve. 
Manifold pressure: (operating): 10” water column (W.C.), 
(non-operating): 11.2” water column (W.C.).
 
 
LP Gas Cylinder must be fitted with Overfill Protection Device 
(OPD). 
 
LP GAS HOOK-UP: 
Ensure that the black plastic grommets on the LP cylinder 
valve are in place and that the hose does not come into 
contact with the grease tray or the grill head. 
 
CONNECTION: 
Your grill is equipped with gas supply orifices for use only with 
liquid propane gas. It is also equipped with a high capacity 
hose/regulator assembly for connection to a standard 20lb. LP 
cylinder (18-1/4” high, 12-1/4” diameter). 
 
To connect the L.P. gas supply cylinder: 
1.  Make sure tank valve is in its full off position (turn 
clockwise to stop). 
2.  Check tank valve to ensure it has proper external male 
threads (type 1 connection per ANSIZ21.81). 
3.  Make sure all burner valves are in the off position. 
4.  Inspect valve connections, port and regulator assembly. 
Look for any damage or debris. Remove any debris. 
Inspect hose for damage. Never attempt to use damaged 
or obstructed equipment. See your local LP gas dealer for 
repair. 
5.  When connecting regulator assembly to the valve, hand 
tighten the nut clockwise to a complete stop. Do not use a 
wrench to tighten. Use of a wrench may damage the 
quick coupling nut and result in a hazardous condition. 
6.  Open the tank valve fully (counterclockwise). Use a soapy 
water solution to check all connections for leaks before 
attempting to light the grill.    See below. If a leak is found, 
turn the tank valve off and do not use the grill until a local 
LP gas dealer can make repairs. 
 
To disconnect LP gas cylinder: 
1.  Turn the burner valves off. 
2.  Turn the tank valve off fully (turn clockwise to stop). 
Detach the regulator assembly from the tank valve by turning 
the quick coupling nut counterclockwise 
 
 
 
 
GAS HOOK-UP     
   
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
K15Y06P-1