Yamaha SP2060 V1.2 Owner's Manual

Page of 56
References
SP2060 Owner’s Manual
Fore
w
o
rd
Netw
ork Settings
Ref
erences
P
anel Operation
Intr
oduction 
to the SP2060
The Contr
ols 
and Connector
s
46
Display Messages
Warning and error messages
* Do NOT turn off the power to the SP2060 while the unit displays the message “DO NOT TURN OFF!” at the bottom of the display.
Message 
Meaning 
Action
Duplicate IP Adr. 
Duplicate IP addresses. 
Change the IP addresses so that there are no duplicates. 
Illegal MAC Adr. 
An illegal MAC address has been encountered. 
This could be due to a hardware malfunction. Refer this 
problem to a contact a Yamaha dealer.
Invalid IP Adr. 
The IP address is not set properly. 
Set an appropriate network IP address. 
Network Error 
A cable is disconnected, the power to the 
connected switching hub or router is turned off, or a 
cable is not in proper condition. 
Connect the cables properly, and make sure that the hub 
and/or router are operating correctly. 
No MAC Adr. 
MAC address not specified. 
This could be due to a hardware malfunction. Refer this 
problem to a Yamaha dealer.
No Battery 
The internal battery is completely discharged or not 
installed. 
If you turn off the power to the unit, the current settings will 
be lost and reset to the default values. Stop operating the 
unit, and contact a Yamaha dealer for battery replacement. 
Critical Battery 
The internal battery is almost discharged. Your data 
may be lost. 
If you turn off the power to the unit, the current settings may 
be lost and reset to the default values. Stop operating the 
unit, and contact a Yamaha dealer for battery replacement.
Low Battery 
The backup battery voltage is low. 
This does not affect the operation of the unit. However, if you 
continue using the unit, the settings may be lost and reset to 
the default values. Contact a Yamaha dealer for battery 
replacement at your earliest convenience. 
Recovering 
A program update attempt has failed, and the 
previous program is currently being restored. 
Do NOT turn power off while the unit is displaying this 
message. If the update attempt repeatedly fails, there may 
be a hardware malfunction. Refer this problem to a Yamaha 
dealer.
Scene Recall Err
A scene recall attempt has failed.
Recall the scene again.
If the problem persists, contact a Yamaha dealer.
Saving Failed 
A save operation has failed. 
This could be due to a hardware malfunction. Refer this 
problem to a Yamaha dealer.
Param Access Err 
Current setting cannot be displayed. 
Save the current setting by using DME Designer, then 
initialize the unit. If the problem persists, contact a Yamaha 
dealer.
Param Set Err 
Current setting cannot be changed. 
W.Clk Unlocked 
A usable word clock signal is not being received or 
cannot be detected. 
Recheck all word clock connections and internal 
parameters. 
DevGrp Sync Err
The device group configuration set via DME 
Designer does not match the real configuration.
Use DME Designer to go off-line, create a configuration that 
correctly matches the actual configuration, and then go 
back on-line to synchronize the configuration.
System Error
A system error has occurred.
Save the current setting by using DME Designer, then 
initialize the unit. If the problem persists, contact a Yamaha 
dealer.