Yamaha PJP-50R User Manual

Page of 53
45
ADDITIONAL 
INF
O
RMA
T
IO
N
English
You can send information or an event which occurs in the system of this unit to another unit as a message (this is called 
“syslog”). “Syslog” contains information such as the start/shutdown of this unit, the login, the activity in normal states, 
and the states of an error. You can specify the level of the message if necessary.
1
In the Web menu, click “Syslog Setting”.
The “Syslog” window appears.
2
Select the desired mode(s) which specifies 
the kind of the message that is sent and 
click.
y
You can select the check boxes of multiple modes.
• Debug Mode: Sends the debug log to confirm the 
inner activity when an error occurs.
• Info Mode (Default): Sends the operation log such 
as the event or states of the activity of this unit.
• Notice Mode: Sends the details of the operation 
log when this unit is in the normal state.
3
In the “Syslog Network Output”, click 
“Enable”.
4
In the “Syslog Host Address”, enter the host 
IP address of the destination unit.
5
Click “Submit”.
The Syslog message specified in step 2 is sent to the 
host address specified in step 4.
Confirming the System Log Message of This Unit (Syslog)