Configuration Troubleshooting
Problem
Solution
No Connection
Physical Link problem. Check to see if the port LED is lit. If 
the LED port is not lit, then you may have a bad cable 
connection.
OR
Configuration Error. Connect through the console port (See 
Chapter 10). Use the 
ifconfig
 command to see all of the 
configured interfaces on the Ethernet Switch Blade and their 
IP addresses. Check to make sure that the IP address of the 
switch and the subnet mask are properly set. Also, the section 
on No Connection for more information. 
Decreased throughput 
You should make sure that your network topology contains no 
data path loops. Between any two end nodes, there should be 
only one active cabling path at any time. Data path loops will 
cause broadcast storms that will severely impact your network 
performance. See the section on Diminished Network 
Throughput
.
High Error Rates, Decreased 
Throughput 
If the interfaces on the Ethernet Switch Blade and the node 
board are not set to auto by default, the link may not negotiate 
correctly. See the section on Connecting to Devices with Fixed 
Port Speeds
Ext FLT LED on 
The EXT FLT LED indicates that communications could not 
be established with one or more remote partner devices on an 
active port or ports. Ports which were configured to be up (via 
i
fconfig
), but do not have remote partner devices attached, 
can cause the EXT FLT LED to be lit, even if there are no 
hardware problems with the switch. See the Network 
Configuration Problems
 chapter for more information 
Ekey Disabled
By default, if there is no device plugged into a node slot in the 
ATCA chassis, the Shelf Manager will 
ekey
 disable the port. 
If a node board is inserted and the ports on the Ethernet Switch 
Blade are still 
ekey
 disabled by the Shelf Manager, check to 
see if the node board has been properly activated by the Shelf 
Manager. 
Determining ekey status for a specific slot
You can determine the current state of any link by using the 
zlc
 command. The 
zlc
 command 
will output the current status of any/all Ethernet ports and their 
ekey
 status that was set by the 
Shelf Manager.
Ethernet Switch Blade User's Guide