E&M Ports
7-11
7.3.2
Test Screen
The Test option facilitates testing and maintenance by allowing you to monitor and set the 
status of the analog interface leads, and to monitor or set the value of the A, B, C, and D 
signaling bits of all E&M circuits on that port. In cross-connect systems, the test option also 
allows you to apply test patterns and tones towards the user and network sides of the system.
Figure 7-8 shows the E&M port Test Screen parameters,Table 7-3 lists some actions you can 
perform from this screen, and Table 7-4  shows the settings for each parameter.
Figure 7-8. Typical E&M port Test Screen
Note:
The above screen shows the ABCD bits as sent by the Tx and Rx sides. The “c” 
indicated on ports 3 and 4 indicate that the bits displayed will then be run through the 
TABS conversion table as seen in 
Table 7-3.
Table 7-3.  Test Screen Actions 
Table 7-4. Test Screen Option Settings and Defaults
Action
Function
Save
Saves changes to settings.
Undo
Returns all settings to the last saved state.
Refresh
Updates certain time-related information fields that are not automatically 
updated (i.e. performance and test data).
Main
Returns to the E&M port Main Screen. If changes are made to settings and 
not saved, you will be prompted to save or lose changes.
Parameter
User Options
Default
TEST
off     on
off
Tx ABCD
mon     set
mon