VXi Computer Hardware VX1410A User Manual

Page of 360
STATus Subsystem
VX1410A & VX1420A IntelliFrame Mainframe Instruction Manual
3–57
STATus:QUEStionable:BLOWer?
Queries the contents of the Blower Event register.  A value of one in a bit
indicates the corresponding condition bit changed from false to true and that
there may be a problem with one of the fans. Unused bits always return a value
of zero. The register is cleared by the *CLS command.
There is no command associated with this query.
    
Parameter
Query response
Not applicable
<NR1>
Blower status word bits
Definition
D0
Blower 1
D1
Blower 2
D2
Not Used
D3
Not Used
D4
Not Used
D5
Not Used
D6
Not Used
D7
Not Used
D8
Not Used
D9
Not Used
D10
Not Used
D11
Not Used
D12
Not Used
D13
Not Used
D14
Not Used
D15
Not Used
0
None
Syntax
Parameters
Reset Value
Errors and Events