Z Microsystems SL User Manual

Page of 51
Doc# 27-0032UM Rev A Issued 07/05
47
COMMAND CONSOLE SERIAL CONTROL ICD
The following serial port property settings must be in place in order for the host to have 
communication with the display. 
SPEED   
19,200 BPS
DATA BITS 
8
PARITY   
None
STOP BITS 
1
FLOW CONTROL  None
The serial control ICD commands are presented here for the user’s knowledge. The 
commands are written and controlled by Z Microsystems and are not intended for the 
customer to use. Any improper use of the commands may place the panel in an unstable 
state and may degrade the image quality, thereby voiding the warranty by the user. 
Command Structure
The command structure for the majority of the commands for the display follow the follow-
ing structure:
Z<space>U<space><command><space><argument>
where... 
“command” = the ascii string that represents the command
“argument” = the optional argument to the command
“space” = ascii character 0x20
The command structure must be succeeded by a carriage return (0x0D).
The controller returns a string of tildes (‘~’) indicating that the command has been ac-
cepted and processed. Some of the commands return other information which will be 
specified on a per command basis.
Unless otherwise specified the command strings examined in this document must be 
placed in the above structure when being sent to the controller.
The commands will be broken down by the image on which it operates (i.e. the main im-
age). There may be overlap between the different images and the commands that work on 
them.
Main Image—Standard Command Structure
The following commands operate on the main image.
PAA
Description 
PAA has the controller perform its auto adjust algorithm. This often helps the main image 
properly position itself if an uncommon image stream is provided to the display.
APPENDIX